background image

* Specifications are subject to changes without notice.

User Operation Guide

08

09

BUTTON LAYOUT

The UI layout on the touch panel can be configure into the following:

Note:

Physical UI Layout Size:  63mm x 49.5mm
Active Widows Area: 

59mm x 46.5mm

To configure the UI layout, a separate firmware is required to be loaded. Firmware could be obtained from ABtUS Singapore on request.

212C Touch panel layout

212C Touch panel layout

REPLACEMENT OF UI DESIGN

Procedure of having the designed UI replaced :

Example : 

UI layout design in Landscape and Portrait

*UI designed is completely customizable. Users can design their own labels to be printed on transparencies (63x49.5mm) and cut out for use.

Latch

Summary of Contents for A934-212C-044

Page 1: ...In Room Control Panel ABtUS SINGAPORE PTE LTD www abtussingapore com Model A934 212C 044 User Programmable Touch Control Panel com ...

Page 2: ... Software allows customized programming such as macros setting feedbacks control commands etc Another characteristic of the panel is the panel button layout and design it can be easily customized and printed on standard transparencies with icons or clear text buttons Automatic backlight fade out Macro definitions setting can be assign for every single button up to 16 different order Default 3x4 ma...

Page 3: ...ftware can be downloaded from download center in ABtUS Singapore s website or at http www abtussingapore com download E12C_V2 2E 100617 zip Note USB to Serial cable adaptor is commercially available and not provided with the A934 212C 044 touch panel Please check that the driver for the adaptor have been properly installed before connecting the device Connecting of cables to A934 212C 044 3 8mm Te...

Page 4: ...ncheck for Return Command link Max two return command is allowed 7 RX UP Bytes Total length for the Data entered Max 15 bytes 0F in Hex per function 8 RX UP Data Function Command code entry Hex code ONLY 9 Macro Macro setting 10 Macro Delay Delay time for macro function 1 to 15sec With interval of 1 0 5sec 11 Macro Link Macro link Physical or Virtual button number 12 Save Save each button function...

Page 5: ...quest out REPLACEMENT OF UI DESIGN Procedure of having the designed UI replaced Example UI layout design in Landscape and Portrait UI designed is completely customizable Users can design their own labels to be printed on transparencies 63x49 5mm and cut out for use Latch ...

Page 6: ...UPLOAD OF PROGRAM Specifications are subject to changes without notice 11 el accordingly ...

Page 7: ... button command code have been set the function name and Baud Rate setting of each button can then be Name and Set accordingly Once all of the above is completed the program can then be uploaded to the Touch Control Panel accordingly Please refer to the procedure in Upload of Program for further instructions ...

Page 8: ...ve been set the function name and Baud Rate setting for each button can then be Name and set accordingly Once all of the above is completed the program can then be uploaded to the Touch Control Panel accordingly Please refer to the procedure in Upload of Program for further instructions ...

Page 9: ...17 ereas UP will EXAMPLE UP SETTING ...