background image

PAGE 50

ABTRONIC™TX USER MANUAL

For transmitters rated at a maximum output power not listed above, the 

recommended  separation  distance  d  in  meters  (m)  can  be  estimated 

using the equation applicable to the frequency of the transmitter, where 

P  is  the  maximum  output  power  rating  of  the  transmitter  in  watts  (W) 

according to the transmitter manufacturer.

NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher 

frequency range applies.

NOTE 2: These guidelines may not apply in all situations. Electromagnetic 

propagation  is  affected  by  absorption  and  reflection  from  structures, 

objects and people.

Summary of Contents for TX

Page 1: ...USER MANUAL ...

Page 2: ...TRONIC TX TENS pain Relief Device Please read this manual before first use Read before you use ABTRONIC TX should never be used to mask or relieve undiagnosed pain Before treating any symptoms of pain it is mandatory to diagnose the cause of pain by a medical professional ...

Page 3: ...designed using ultra thin and flexible medical grade silicone to perfectly match the contour of your body This complete new approach to relieve pain offers a safe and effective non drug treatment alternative for you Your body s natural warning signs of cramps acute pains migraines injuries resulting in pain and chronic pain can be unsettling and need to be relieved ...

Page 4: ...ject to wear and tear Please replace the gel pad if it stops providing sufficient contact if you start to get and unpleasant feeling when using the device or if the device does not stick to the skin properly any more If it is not replace skin irritation may result Advanced circuitry conserves energy by providing 10 mins per treatment up to 100 sessions per battery life time ...

Page 5: ... pain by stopping the pain gate to prevent pain signal transmission to the brain and helps to release endorphin to sooth pain by stimulating nerves It is free from side effects when used properly and can be used as a simple means of self treatment The method is scientifically proven and a medical approved method Your GP must check any symptoms to be treated with TENS and must give instructions how t...

Page 6: ...PAGE 6 ABTRONIC TX USER MANUAL ON HI Button increase Intensity OFF Low Button decrease Intensity LED Light 2 LED Light 1 ...

Page 7: ...creases the output intensity Press once to increase the output intensity The higher the intensity the larger the contraction To adjust to maximum output power you need to push this button 10 times 2 OFF LOW Each pressing of this button decreases the intensity by one step down until the unit turns off ...

Page 8: ...ription GREEN GREEN AbTronicTX controller is now operating Both Led light will keep flashing The flashing speed is proportion to the output intensity For the Max Power output both LED will be always light up RED Low battery indication RED RED The pad contact with user body is no good OFF OFF Unit switch off ...

Page 9: ...PAGE 9 CYCLE MODE PULSE WIDTH PULS RATE ON TIME 1 Constant 200 70 Hz 120 s 2 Burst 200 70 Hz 120 s ...

Page 10: ...SER MANUAL OPERATION BATTERY 1 Open the battery door by pushing it in the direction of the arrow 2 Insert one piece CR 2032 Lithium battery into the battery compartment The positive pole of the battery should be facing you ...

Page 11: ...PAGE 11 BASIC USE 1 Attach the Abtronic TX control unit onto the silicon pad holder Insert the controller by aligning the marking on the controller case with the holder ...

Page 12: ... 12 ABTRONIC TX USER MANUAL Insert the control unit aligning it with the shorter marking on the holder at position 1 and turn it clockwise until it aligns with the longer marking on the holder at position 2 ...

Page 13: ...ht result in burns Always stick gel pad to all electrodes while using the product Don t apply the product directly to skin this may be painful or cause irritation or burns Precautions 1 Take the gel pad out of the bag and peel off one side of the protective film from the gel pad ...

Page 14: ...TX USER MANUAL 2 Stick the gel pad onto each of the 2 conductive areas on the rear side of the stimulation pad If there is an air bubbles under the gel pad use a finger and press the air to the side of the pad to escape ...

Page 15: ...PAGE 15 3 After affixing all gel pad properly peel off the remaining film Do not peel off the gel pad affixed to the electrode until you need to replace them with new ones ...

Page 16: ...PAGE 16 ABTRONIC TX USER MANUAL 4 Gel pad Storage After use do NOT remove the gel pad but always place protective board back to electrode after use ...

Page 17: ...nly remove the gel pad if you need to replace them with new ones 2 Turn off the product before removing the gel pad Otherwise this may cause pain or irritation 3 Peel off the complete gel pad slowly in one piece Remove any remaining gel on the electrodes ...

Page 18: ...Pain Pain after injuries to musculoskeletal system Pain with circulatory problems Chronic pain through various causes Please see the diagram with recommended placement However the ABTRONIC TX is a personalized tool and can be adapted to suit the individual If the below placement are not effective please the unit over the area closest AFTER you have placed the unit onto your skin switch the control...

Page 19: ...PAGE 19 BACK FRONT ...

Page 20: ...utton repeatedly The LED light up and the flashing speed is proportion to the output intensity If you do not feel any stimulation reposition the product 1 2 cm at a time up or down until you find the trigger points for the muscle stimulation Please turn the unit off before repositioning Hint DO NOT USE gel or creams that contain oils with the product ...

Page 21: ...PAGE 21 3 Push the ON HI button several times to carefully increase the intensity Adjust the intensity according to your comfort level You should feel a light tingling ...

Page 22: ...tton OFF LOW you decrease the intensity by one step To switch the unit off press the OFF LOW button several times until the LED lights go off The unit has an auto timer For your convenience it will shut off after 10 minutes of operation Push HI button 10 x to increase intensity 10 steps Push LOW button 10 x to decrease intensity 10 steps 0 1 2 3 4 5 6 7 8 9 10 ...

Page 23: ...uctive area silver colored area does not touch the skin the intensity can only be set up to 1 If ABTRONIC TX is removed during use the intensity is automatically reset to 1 If it is not placed back into contact with the skin the unit will turn off after 20 seconds The auto timer will shut off after 10 minute operation ...

Page 24: ... is a great way treating pain from certain causes It may take a few moments of practice for locating it correctly and provides the best results for you Important Notes If there is no gel pad on the ABTRONIC TX or if it is not placed tightly against the skin an uncomfortable tingling sensation can occur This can also happen if the body has built up excessive oils on the skin Before each use please ...

Page 25: ... removal of the ABTRONIC TX from your skin this could be caused by the gel pad been worn our already For safety and to avoid unnecessary discomfort please ensure that the intensity settings are set to zero before placing and removing the machine Hint VERY IMPORTANT You MUST apply a gel pad to ABTRONIC TX that is not worn or dirty The ABTRONIC TX must make contact with your skin It will not work th...

Page 26: ...ced Do NOT immerse it in water or other liquids Do not rub hard on the conductive areas Do not wash it in the washing machine or apply fabric conditioner NEVER BEND the conductive pad A discoloration of the conductive area and a crumbled look after many uses however is normal Wear and tear is not covered by the guarantee It should be noted however that this is the most advanced generation design a...

Page 27: ...ll lit up The electronic control unit is built very reliable and uses SMT technology It is maintenance free and will give you many many years of trouble free usage CARE AND CLEANING IMPORTANT PLEASE READ Do not wash the unit in the washing machine or chemical cleaners as this can damage the unit Do not dry clean Do not use bleach Clean the unit with a slightly wet sponge with detergent and wipe wi...

Page 28: ...an also happen if the body has built up excessive oil on the skin DO NOT bend the conductive areas Worn or dirty conductive gel pad can reduce the performance of the unit or cause the belt to feel erratic The conductive gel pad are a consumable item and do wear out eventually Wear and tear is not covered by the guarantee ...

Page 29: ... discomfort stop using it immediately Pause ABTRONIC TX before remove move stimulate region Use only for the specific pain problem diagnosed by professionals Consult your local authorities for proper battery form battery chamber if you are not going to use it for a long period ...

Page 30: ...h or on diseased skin Do not use this unit in places with high humidity such as the bathroom May need to use under the supervision of a physical therapist For external use only Long term stimulation at the same site may cause skin discomfort Consult a dermatologist if skin discomfort persists ...

Page 31: ...device if you receive other medical treatments Do not disassemble or remodel this unit Do not use this unit while sleeping driving or bathing Prevent any metal object such as belt buckle or necklace coming into contact with ABTRONIC TX Supervision and medical consultancy recommended if you are under age 16 ...

Page 32: ...ANUAL TROUBLE SHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION LEDs do not light up at all Batteries are not installed Batteries are installed incorrectly Batteries are empty Install batteries Check polarity sign Replace batteries ...

Page 33: ...ad correctly Controller hang up Battery is low Use gel pad on conductive pad and place it directly onto skin Check that controller is connected firmly with ABTRONIC TX pad Increase intensity by pushing the up button Perform a RESET remove Batteries for 1 minute for full RESET Replace Battery ...

Page 34: ... AbTronic TX is positioned Incorrectly gel pad are worn or have oil deposits Battery is low Increase intensity by pushing the up button Make sure the gel pad are still adhesive Otherwise use new gel pad Move the AbTronic TX around to locate your trigger points switch off when moving Replace gel pad Replace Battery ...

Page 35: ...PAGE 35 LEDs light up but all buttons do not work Microprocessor hang up Battery is low Perform a RESET remove batteries for 1 minute for full RESET Change Battery ...

Page 36: ... MANUAL IMPORTANT POWER RESET If the unit does not switch on or if you can t change to different programs the microprocessor may have hanged Please perform a simple RESET by removing batteries and replace them after one minute ...

Page 37: ...based on 500 Ω load 10 Treatment Time 10 minutes auto off Pulse Strength 0 15 stages adjustable Operation Environment 10 40ºC 30 85 Relative Humidity Storage Environment 10 50ºC 10 95 Relative Humidity Transportation Environment 10 50ºC 35 85 Relative Humidity Barometric Pressure 70kPa 106kPa Size 110 x 115 x 19mm ...

Page 38: ...QUIPMENT and SYSTEMS Guidance and manufacture s declaration electromagnetic emission The ABTRONIC TX is intended for use in the electromagnetic environment specified below The customer or the user of the ABTRONIC TX should assure that it is used in such and environment ...

Page 39: ...romagnetic environment guidance RF emissions CISPR 11 Group 1 The ABTRONIC TX uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment ...

Page 40: ...itable for use in all establishments other than domestic and those directly connected to the public low voltage power supply network that supplies building used for domestic purposes Harmonic emissions IEC 61000 3 2 Class A Voltage fluctuations flicker emissions IEC 61000 3 3 Complies ...

Page 41: ...nd SYSTEMS Guidance and manufacture s declaration electromagnetic immunity The ABTRONIC TX is intended for use in the electromagnetic environment specified below The customer or the user of ABTRONIC TX should assure that it is used in such an environment ...

Page 42: ... 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floor are covered with synthetic material the relative humidity should be at least 30 Electrical fast transient burst IEC 61000 4 4 2 kV for power supply lines 2KV for power supply lines Mains power quality should be that of a typical commercial or hospital environment ...

Page 43: ...e to ground Mains power quality should be that of a typical commercial or hospital environment Power frequency 50 60Hz magnetic field IEC 61000 4 8 3A m 3A m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment ...

Page 44: ... UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Mains power quality should be that of a typical commercial or hospital environment If the user of the ABTRONIC TX requires continued operation during power mains interruptions it is recommended that the ABTRONIC TX be powered from an uninterruptible power supply NOTE UT is th...

Page 45: ... not LIFE SUPPORTING Guidance and manufacture s declaration electromagnetic immunity The ABTRONIC TX is intended for use in the electromagnetic environment specified below The customer or the user of the ABTRONIC TX should assure that it is used in such an environment ...

Page 46: ...eparation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance 80 MHz to 800 MHz 800 MHz to 2 5 GHz Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in metres m Field strengths from fixed RF transmitters as determined by an e...

Page 47: ...dcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the ABTRONIC TX is used exceeds the applicable RF compliance level above the ABTRONIC TX should be observed to verify normal operation If abnormal per...

Page 48: ...se in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the ABTRONIC TX can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the ABTRONIC TX as recommended below according to the maximum output power of the communications equipment ...

Page 49: ...m output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz 80 MHz to 800 MHz 800MHzto2 5GHz 0 01 0 35 0 12 0 23 0 1 1 1 0 37 0 73 1 3 5 1 2 2 3 10 11 3 7 7 3 100 35 12 23 ...

Page 50: ...the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people ...

Page 51: ......

Page 52: ...This product is brought to you by AbTronic by Red Lemon Incorporation www abtronic co by Red Lemon Incorporation MMXV RLTX Eng V1 4 97x97 ...

Reviews: