3D. Standard Operating Procedures
NOTE: To assure a long trouble-free service life of the ATLAS/TITAN/MAGNUM 30-200
Ozone Generators, provide following operating conditions:
• Make sure that the oxygen concentrator is maintained properly and is producing
oxygen at greater than 90% purity and less than -60°C dew point. Check sieve
conditions and replace it as often as recommended by manufacturer
• Install oxygen filter and oxygen dryer between oxygen concentrator and the Ozone
Generator, check condition and replace a cartridge as to protect Ozone
Generator from sieve particles in case of oxygen generator failure and moisture.
• Make sure to maintain working pressure across ozone cell as specified for the
generator protection and most e
ffi
cient ozone production.
• When injecting ozone in to water make sure to protect the generator from
flooding
by installing
ALD 2000 Flood Prevention device (can be supplied)
capable of preventing water backup
Check valves usually
start leaking after few
days of operation in ozone and cause serious damage to the ozone cell. We
recommend using devices, which could automatically drain water out of ozone
line and stop it from entering the ozone cell.
• Protect internal components of the Ozone Generator from water, snow, excessive
dust
, dirt,
humidity, vibration,
and/or
mechanical shock; make sure that there is a
sufficient amount of clean air available for the unit cooling air
and inlet and
outlet are not obstructed by other equipment or elements.
• Check that electrical power fluctuations are /- 10% of the specified AC
Voltage and install power-conditioning devices if necessary.
ABSOLUTE
OZONE®
Section 3
-12-
For more information about this product visit our
website at, http://www.absoluteozone.com
OPERATOR’S MANUAL