SECTION 2 INSTALLATION
2E. Remote Control
4-20mA On/Off Power Remote Control
• Remote control of ozone production level by 4-20mA at 10 V signal,
no special switching for both of these signals required
• Remote On/Off. Remote Switch must be normally open for the gen-
erator to be “On” and closed to stop the Ozone production.
• That switch has to be connected to dry contacts only (not connected
to the ground on any kind or to any voltage source AC or DC)
• Remote Ozone Generator status indicator.
a. During Normal Ozone generator operation pin 5 is normally
open, pin 6 commons, pin 7 is normally closed.
b. If Remote Control Switch is off or safety shutoff is activated
the circuit will be closed between pins 5 & 6.