Transducer Instruction Manual 

Range:   

LETIX 

Type: 

 

L-ANV-0-0-R-AC 

Revision:   

V1.0 

1.

 

General Description

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The LETIX Digital Web Tension Indicator continuously displays the true web tension either as a 
percentage of total tension or in real engineering units. 
 
The measurement of actual web tension is made by sensing, with strain gauge transducers (sometimes 
referred to as 'load cells'), the force on a sensing roller caused by the tension in the web. The electrical 
signal from the transducers is a combination of tension force and sensing roller deadweight.  
 
The effect of the weight of the sensing roller is removed electrically, leaving the tension force signal only 
to be displayed on the meter. 
 
The LETIX indicator uses high specification A/D and D/A converters, power supply, and a bright LED 
digital display, all housed in a standard DIN size case. The LETIX features as standard a transducer bridge 
supply excitation of 5v (or 10v) DC, an independently scalable digital display and an isolated analogue 
output (0 to +10V at 2mA maximum).  It can be used as a remote display and/or as the input to a control 
system. 
 
 
 
 
 
 
 
 
 
 
 
 

The Indicator can accept full scale input voltages of either up to +/- 40 mV (foil strain gauges) or up to +/- 
400 mV (semi-conductor strain gauges) for full display with selectable decimal point position and scaling, 
and a zero offset for both positive and negative sensing.

Summary of Contents for L-ANV-0-0-R-AC

Page 1: ...Amplifier Instruction Manual Range LETIX Type L ANV 0 0 R AC Supply 110 240V AC Output 0 10V Revision V1 0...

Page 2: ...s 1 1 General Description 2 2 Installation 3 2 1 Mechanical 3 2 2 Unit Electrical Connection Diagram 3 2 3 Transducer Electrical Connection Diagrams 4 2 4 Supply Connection Diagram 6 3 Supply Voltage...

Page 3: ...n in the web The electrical signal from the transducers is a combination of tension force and sensing roller deadweight The effect of the weight of the sensing roller is removed electrically leaving t...

Page 4: ...icator must be installed in a dry non hazardous location A panel cut out of 92 mm 1 0 0 0 mm x 45 mm 1 0 0 0 mm is required The depth of the Indicator is 125 mm but extra provision must be allowed for...

Page 5: ...ucer Electrical Connection Diagrams Connections for a Cleveland Kidder Classic Semi Conductor Transducer one Half Bridge Transducer Connections for two Cleveland Kidder Classic Semi Conductor Transduc...

Page 6: ...Instruction Manual Range LETIX Type L ANV 0 0 R AC Revision V1 0 Connections for one Cleveland Ultra Semi Conductor Transducer or one Full Bridge Foil Gauge Transducer 1 2 3 4 5 6 Red Green Blue WIRIN...

Page 7: ...C Controls t 0 1732 763278 e sales absolutemeasurement co uk w absolutemeasurement co uk Unit 19 Silver Birches Business Park Aston Road Bromsgrove B60 3EU 6 Transducer Instruction Manual Range LETIX...

Page 8: ...e AC Mains and the screens of the transducers and any other cable should be bonded to earth locally with short leads 4 Calibration 4 1 Indicator This is usually pre set by CMC to the clients needs bef...

Page 9: ...press OK again for display to read for example 0 0 The input calibration is now finished and the tension indicator should read correctly 4 6 Output Signal Calibration Once the tension calibration has...

Page 10: ...eland Kidder Classic and Ultra series and 10v for foil type transducers In addition measure the differential millivolt signal at full transducer load to ensure that the unit is given signals within it...

Reviews: