5

 

Transducer Instruction Manual 

Range:   

Advance 

Type: 

 

ACDF 

 3 

Revision:   

V1.0 

 

2.8 

Hazardous Area Installation - Intrinsic Safety 

 
CMC Controls tension transducers can be located in a hazardous area to provide an Intrinsically Safe 
installation to EN 50039 when a proprietary Zener Barrier module, Part Number 4503, is used. Tension 
transducers are passive components and are classified as simple apparatus by EN 50014. Strain gauge 
transducers (load cells) will be damaged if subjected to the 500 volt insulation test required by EN 50020. 
To comply with Intrinsic Safety regulations the body of the transducer must be bonded to the IS earth 
using 4 square millimetre green/yellow insulated cable. Consult CMC Controls for more information. 
 

NOTE

  It is the responsibility of the user to ensure that all relevant safety regulations are complied with. 

The integrity of all connections particularly the earth should form part of any maintenance procedure. 

2.9 

Single Transducer Operation 

 
Most web tension installations require two transducers, each supporting one end of the sensing roller 
shaft and the transducer output signals are summed to give a measurement of Total tension. For those 
installations where only one transducer is required a Dummy Transducer, Part Number 4431, may be 
needed to complete the full Wheatstone bridge. For single transducer installations the MWF calculation, 
see below, should be derated by a factor of 1.5, consult CMC Controls for more information. 

2.10  Transducer Electrical Connections 

 
The  signal  wiring  between  the  transducer  and  the  indicator  or  controller  must  be  by  screened  cable 
routed well away from any power wiring or other sources of interference. 
 
The 

RED  SPOT

  on  the  transducer  specifies  the  output  signal  polarity  in  relation  to  the  applied  load 

direction.  Depending  on  the  installation  the  transducer  output  signal  can  be  positive  or  negative  for 
increasing  load.  Ensure  the  yellow  and  green  output  leads  are  connected  to  the  indicator  or  controller 
terminals  correctly,  so  that  they  add  to,  rather  than  cancel  each  other.  In  most  installations,  one 
transducer will give a positive signal the other a negative signal. 
 
To  confirm  the  connections  to  the  indicator,  switch  on,  unplug  any  one  of  the  transducer  connectors, 
adjust the  indicator zero control until the meter or display reads approximately zero. Apply a load  to the 
tension  sensing  roller  in  the  same  direction  as  the  resultant  web  tension,  the  display  should  move 
positive. If the display decreases or moves negative, reverse the appropriate yellow and green transducer 
leads at the indicator terminals. Repeat for the other transducer. 
When completed, reconnect both transducers. 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ACDF-3

Page 1: ...Transducer Instruction Manual Range Advance Type ACDF 3 Revision V1 0 ...

Page 2: ...on of Transducer Mounting Location 2 2 2 Installation Precautions 3 2 3 Mounting Surface Preparation 3 2 4 Bearing Lubrication 3 2 5 Sensing Roller Balance 3 2 6 Transducer and Sensing Roller Installation 4 2 7 Temperature Compensation and Shaft Expansion 4 2 8 Hazardous Area Installation Intrinsic Safety 5 2 9 Single Transducer Operation 5 2 10 Transducer Electrical Connections 5 3 Transducer For...

Page 3: ...ing roller shaft The tension force applied to the sensing roller must pass freely through to the transducer which converts this force into an electrical signal This signal is a combination of tension force and sensing roller dead weight The dead weight is zeroed out electrically in the indicator or controller leaving the tension force signal only to be amplified to give a true display of measured ...

Page 4: ...The close concentricity of this mounting spigot to the bearing diameter allows parallel path rollers and thus avoids web tracking problems No appreciable force should be transmitted through the four fixing bolts See the Transducer Dimensions drawing for full details 2 4 Bearing Lubrication The bearing normally fitted by CMC Controls is without seals and has only the bearing manufacturers preservat...

Page 5: ...ers to be reduced by at least 8mm to permit the transducers and roller assembly to fit inside the machine frames for installation The transducers may also be fitted on the outside faces of the frames to allow full use of the machine width Alternatively provision must be made to fit the complete transducers and roller as an assembly into the machine axially The bearing is retained in the transducer...

Page 6: ...haft and the transducer output signals are summed to give a measurement of Total tension For those installations where only one transducer is required a Dummy Transducer Part Number 4431 may be needed to complete the full Wheatstone bridge For single transducer installations the MWF calculation see below should be derated by a factor of 1 5 consult CMC Controls for more information 2 10 Transducer...

Page 7: ...r Tampering or damage caused during installation will invalidate the warranty The signal output from the transducer with the recommended 5 6V DC excitation is 250mV nominal when the transducer is loaded to its maximum working force MWF The transducer has built in mechanical overload stops which operate at approximately 125 of the MWF Forces above 150 of MWF particularly transients or tension snatc...

Page 8: ...citation voltage may be too low 4 3 Wrong Polarity of Output Signal 1 Check that the web path is correct 2 The transducer may be incorrectly orientated rotate 180 to correct this If rotation is not possible interchange the transducer excitation supply or output signal leads at the indicator or controller terminals 4 4 Output Signal Not Linear Zero Shifts During Operation 1 Check that there is no d...