background image

 
 

   

 

 

 

Beware of Electric Shock! 

 

 

To prevent electric shock the device must be properly grounded during 
installation. Do not ignore using the grounding plug, or else there is a risk 
of electric shock. 

 

During a lightning 

storm, please disconnect the device’s power supply, or 

provide other suitable lightning protection. If the equipment is not in use 
for a long time, please unplug the power cord. 

 

When performing any installation or maintenance work (e.g. removing 

the fuses, etc.,) make sure to turn off the master switch. 

 

Disconnect AC power when the product is not in use, or before 

disassembling, or installing the product. 

 

The AC power used in this product must comply with local building 

and electrical codes, and should be equipped with overload and 
ground fault protection. 

 

The main power switch should be installed at a location near the 

product and should be clearly visible and easily reached. This way in 
case of any failure the power can be promptly disconnected. 

 

Before using this product check all electrical distribution equipment, 

cables and all connected devices, and make sure all meet current 
requirements. 

 

Use appropriate power cords. Please select the appropriate power 

cord according to the required power and current capacity, and 
ensure the power cord is not damaged, aged or wet. If any 
overheating occurs, replace power cord immediately. 

 

For any other questions, please consult a professional. 

 

Beware of Fire! 

 

Use a circuit breaker or fuse protection to avoid fire caused by power 
supply cables overloading. 

 

 

 

Maintain good ventilation around the display screen, controller,   

power supply and other devices, and keep a minimum 0.1 meter gap with 
other objects.   

 

Do not stick or hang anything on the screen. 

 

Do not modify the product, do not add or remove parts. 

 

Do not use the product in case ambient temperature is over 50 

 

 

 

Summary of Contents for JP Series

Page 1: ...JP Series User Manual STEP Simple Operation Panel Weight Cooling System Fast Assembly High Brightness Front Servicing High Refresh...

Page 2: ...03 Product Introduction 06 About JP Series 06 Product Specifications 08 Basic Wiring Overview for Hanging Installation Locking System 10 Product Assembly 12 Hanging bar 13 Service and Maintenance 15 A...

Page 3: ...efully before installing powering up operating and maintenance of this product Follow safety instructions in this manual and on the product If you have any questions please seek help from Absen WARNIN...

Page 4: ...a location near the product and should be clearly visible and easily reached This way in case of any failure the power can be promptly disconnected Before using this product check all electrical dist...

Page 5: ...een from within a 1 meter distance Do not use any optical devices that have converging functions to look at the screen to avoid burning the eyes Product Disposal Any component that has a recycling bin...

Page 6: ...for video broadcast result of exhibition and so on JP series includes JP6 25 JP8 33 and JP9 3 The JP series uses aluminum profile die casting aluminum structure and the LED curtain with more than 35 t...

Page 7: ...JP6 25 JP8 33 Up down lock Power box Locating pin Left right lock Up down lock Power box Arc lock Left right lock Power in Power out Date in Date out...

Page 8: ...Single mode fiber 10 km UTP cable 100 m Single mode fiber 10 km UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 4500 5000 3000 Horizontal Viewing Angle 120 140 140 Vertical V...

Page 9: ...allation Notes 1 Hanging bars can load a max height of 16 panels 2 At an input voltage of 220V one power cable can load 16 panels of JP series at an input voltage of 110V one power cable can load 8 pa...

Page 10: ...Locking System Horizontal Locking Procedures...

Page 11: ...Vertical Locking Procedures...

Page 12: ...Product Assembly Procedure Hanging Hanging Installation Fix the Hanging Bar on the Truss Turn the adjustment screw to make the clamps close The hanging bar should be directly affixed to the truss...

Page 13: ...Connect and assemble tiles Hanging bar 0 5m hanging bar...

Page 14: ...1m hanging bar...

Page 15: ...t Maintenance Easy Maintenance for Power Box Step1 Loosen the screws used for fixing module with a cross screwdriver Step2 Replace a good module Step1 Loosen the fixed bolts from the power box Step2 R...

Page 16: ...ng Power Cable Dimension 10m Max Current 16A Name Display DATA cable Dimension 20m Name Panle DATA cabel Dimension 1m Name Sending card Box Dimension W480 H45 D240mm Name Flight case Max Capacity 12 i...

Page 17: ...Flight case LED panels stored horizontally to prevent SMD damage Flight cases are optimised to fit in vehicles for low cost transport Fully stackable to save space 12 in 1 design...

Page 18: ...n Absen Optoelectronic Co Ltd reserves the rights to modify contents without any further notice Shenzhen Absen Optoelectronic Co Ltd 18 20F Building 3A Cloud Park Bantian Longgang District Shenzhen 51...

Reviews: