background image

During installation, make sure all the coffin locks are tightened in the direction of arrow as shown in 

the illustration.

 

 

 

 

Summary of Contents for iCon Series

Page 1: ...iCon series User Manual Shenzhen Absen Optoelectronic Co Ltd...

Page 2: ...Table of content Safety Information 03 Product Introduction 06 About iCon series 06 Product Specifications 07 Product Installation 16 Service and Maintenance 29...

Page 3: ...efully before installing powering up operating and maintenance of this product Follow safety instructions in this manual and on the product If you have any questions please seek help from Absen WARNIN...

Page 4: ...a location near the product and should be clearly visible and easily reached This way in case of any failure the power can be promptly disconnected Before using this product check all electrical dist...

Page 5: ...een from within a 1 meter distance Do not use any optical devices that have converging functions to look at the screen to avoid burning the eyes Product Disposal Any component that has a recycling bin...

Page 6: ...impact of the speech and promote the efficiency of the meeting The iCon series has the following products iCon C110 iCon C138 iCon C165 and iCon C220 In the future according to market demand other sp...

Page 7: ......

Page 8: ......

Page 9: ...ame Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 350 Horizontal Viewing Angle 140 Vertical Viewing Angle 140 Electrical P...

Page 10: ...Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 350 Horizontal Viewing Angle 140 Vertical Viewing Angle 140 Electrical Para...

Page 11: ...icture Frame Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 350 Horizontal Viewing Angle 140 Vertical Viewing Angle 140 Ele...

Page 12: ...Frame Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 350 Horizontal Viewing Angle 140 Vertical Viewing Angle 140 Electrica...

Page 13: ...2 Cabinet dimension figure 3 Module dimension figure...

Page 14: ...Product Components 2 1 Cabinet Introduction 2 2 HDMI cable for vertical connections in between the cabinets 0 5m...

Page 15: ...the cabinets 0 95m 2 4 Power Cable 1 for vertical connections in between the cabinets 0 26 m long Power Cable 2 for vertical connections in between the cabinets 0 5 m long 2 5 Main Power Cable 10 m l...

Page 16: ...e position is the distance from the end face of the beam is 100mm the distance between the upper and lower wall joints is 900mm The distance between the lower frame and the wall joint is 305mm as show...

Page 17: ...a total of 3 use the 3mm hex wrench to screw in the front side does not install the slot connector because the front may need to put the T nut to fix the hanging plate Note There is a tapping on one e...

Page 18: ...hanging plate as shown below Note First screw all T nuts and screws into the middle and side hanging plate waist holes Step 6 Fix the first side hanging plate to the beam and align the side of the han...

Page 19: ...Step 7 Install the side hanging plate and the middle hanging plate from left to right Step 8 Put in the box and lock it...

Page 20: ...l the border and corner Install from the bottom up pay attention to the large frame screw M6x10 fixed frame to the box Step 10 Fixed distribution box ship type switch etc The position is the bottom of...

Page 21: ...iCon C165 E165 installation iCon E192 installation...

Page 22: ...iCon C220 installation...

Page 23: ...umpers to the truss or the steel structure Connect the bumpers together using the metal connectors and make sure they are level Cabinet installation Assemble the cabinets from top down layer by layer...

Page 24: ......

Page 25: ...During installation make sure all the coffin locks are tightened in the direction of arrow as shown in the illustration...

Page 26: ...source to the screen please check power and data cables connections carefully and make sure they are wired correctly Use a multimeter to test the L N and PE lines in AC power input port and make sure...

Page 27: ...reen power cable can carry up to 32 cabinets ie iCon C110 iCon E110 iCon C138 iCon E138 screen comes standard with 1 3 2 5mm screen power cord iCon C165 iCon E165 iCon E192 iCon C220 screen comes stan...

Page 28: ...MI Cabling Notes The signal line adopts HDMI cable and the S type is connected up and down Please calculate the resolution according to each box pixel Each HDMI cable can control up to 1920 1080 pixel...

Page 29: ...ervice tool clockwise all the way Step 2 Place the front service tool onto the module tightly and rotate the two rotation handles counterclockwise all the way Step 3 Hold the two handles on the tool a...

Page 30: ...a multi meter to test the AC input L N PE and DC output VCC GND to determine whether there is a short circuit If a short circuit has been found please examine the circuit carefully Power up the cabine...

Page 31: ...n Absen Optoelectronic Co Ltd reserves the rights to modify contents without any further notice Shenzhen Absen Optoelectronic Co Ltd 18 20F Building 3A Cloud Park Bantian Longgang District Shenzhen 51...

Reviews: