4. Appendix 

(continued)

IAR version table

» Since IAR GUI requires different SDK DLL to be developed and supported for each version, it is not easy to 

manage and distribute the SDK DLL.

14

IAR version

Detailed version: released year

Matched SDK DLL version

8.1

10.30.x : 2019

10.30

8.0

10.20.x : 2018

10.10

8.0

10.10.x : 2017

10.10

7.3

9.30.x : 2016

9.30

7.2

9.20.x : 2015

9.20

7.0

9.10.x : 2014

9.10

6.5

8.30.x : 2013

8.30

6.4

8.20.x : 2012

8.20

6.1

8.11.x : 2012

8.10

6.1

8.10.x : 2011

8.10

Summary of Contents for EW8051

Page 1: ...E OCD II OCD OCD II EW8051 Setup Guide IAR EW8051 Compiler and Debugger MDS...

Page 2: ...on 2 2 ABOV s SDK DLL Connections 3 Use of IAR Debugger 3 1 Download Hexfile 3 2 Cautions for Debugging 4 Appendix 4 1 SDK DLL Compatibility according to IAR Versions 4 2 Number Limitation of Built in...

Page 3: ...t How to connect and detect the OCD OCD II E OCD II dongle How to detect ABOV s 8051 device How to debug ABOV s device This user guide describes restrictions under the 8051 debugger of IAR C SPY envir...

Page 4: ...he built in HID it can be used immediately after connecting to PC OCD OCD II dongle It requires an installation of Kernel Driver on a PC While operating the OCD Debugger Setup Program that is provided...

Page 5: ...sources of IAR SDK DLL compatibility between IAR versions It needs to remember that IAR SDK DLL is compatible according to IAR versions Causes Problem of IAR itself compatibility problem When the vers...

Page 6: ...Confidential 2 IAR Debugger Connections continued IAR project settings Select Options then select Debugger Press OK button to connect to the Third Party Driver 6...

Page 7: ...ons continued IAR Third Party Driver settings Select Options then select Debugger Finally select Third Party Driver Press OK button to connect to an SDK DLL file provided by ABOV Check the IAR version...

Page 8: ...ebugging button you can proceed operations consecutively Detect OCD OCD II E OCD II dongle For each dongle select POR Power on Reset for the series to which a target device belongs When connecting OCD...

Page 9: ...t is turned off a dialog box is displayed as shown below If the target is turned on but an unregistered product is detected a dialog box is displayed as shown below When the target is detected normall...

Page 10: ...ial 3 Use of IAR Debugger continued If a target device has options After downloading a Hex file the corresponding option dialog for the device is displayed Example option dialog for MC96F8204 is shown...

Page 11: ...Confidential 3 Use of IAR Debugger continued 3 2 Cautions for Debugging Use the functions of IAR debugger without changes Remember only that the number of Breakpoints is limited 11...

Page 12: ...s for each device is different It displays the number of Breakpoints available for developers except for Breakpoints used by IAR debugger It displays a warning message if a developer sets a larger num...

Page 13: ...Some of SDK DLL are not compatible if their Embedded Workbenches have different versions As of 2019 ABOV supports the version 8 0 and 8 1 of Embedded Workbench Check the IAR version by following the...

Page 14: ...it is not easy to manage and distribute the SDK DLL 14 IAR version Detailed version released year Matched SDK DLL version 8 1 10 30 x 2019 10 30 8 0 10 20 x 2018 10 10 8 0 10 10 x 2017 10 10 7 3 9 30...

Page 15: ...be managed with the reduced number of Breakpoints Products that reduces number of Breakpoints to 4 2 or 1 are released Number of reserved Breakpoints for each GUI ABOV s debugger N A KEIL 2 to 3 The...

Page 16: ...6P1102 A96G181 A96R717 MC93F5509 MC95FR464 MC96F6432 MC96F7848C MC96FC832 MC96FM408 MC96FR332B MC96FT1516B MC96P6608 A96L302 A96R725 MC95FB204 MC95FT081 MC96F6508A MC96F7864 MC96FC832A MC96FR112C MC96...

Page 17: ...Confidential 5 End of Document End 17...

Reviews: