Abode Tubist T Spray Installation Instructions Download Page 2

 

Correct

 

use

 

of

 

Flexible

 

Hose

 

Connectors

 

 

If

 

this

 

product

 

is

 

supplied

 

with

 

flexible

 

hose

 

connections

 

for

 

ease

 

of

 

installation

 

you

 

must

 

observe

 

the

 

conditions

 

below,

  

failure

 

to

 

observe

 

these

 

standard

 

installation

 

guidelines

 

will

 

invalidate

 

the

 

warranty

 

for

 

your

 

product.

 

 

 

   

 

 

Always

 

screw

 

the

 

flexi

 

hoses

 

into

 

the

 

product

 

only

 

by

 

hand,

 

until

 

feeling

 

mechanical

 

rest,

 

a

 

spanner

 

must

 

not

 

be

 

used

 

on

 

the

 

product

 

end

 

of

 

the

 

connecting

 

hose.

 

 

Always

 

use

 

the

 

pipes

 

provided

 

and

 

not

 

an

 

alternative

 

substitute

 

 

The

 

braiding

 

on

 

the

 

flexible

 

hose

 

must

 

not

 

be

 

in

 

contact

 

with

 

anything

 

else,

 

for

 

example

 

chemicals,

 

internal

 

or

 

external

 

room

 

walls

 

or

 

dissimilar

 

metals

 

or

 

materials

 

or

 

sharp

 

objects.

 

 

 

          

 

Never

 

twist

 

or

 

stretch

 

the

 

flexible

 

hose

 

during

 

installation.

 

 

Do

 

not

 

overtighten

 

the

 

hexagonal

 

end

 

of

 

the

 

hose

 

connecting

 

to

 

the

 

supply

 

feeds

 

when

 

using

 

a

 

spanner

 

causing

 

the

 

hose

 

to

 

twist.

 

 

 

 

 

Hoses

 

must

 

not

 

be

 

double

 

bent

 

in

 

multiple

 

directions

 

kinked

 

or

 

looped

.

  

 

Observe

 

the

 

minimum

 

bend

 

radius

 

of

 

50mm.

 

 

 
 

 

 

Before

 

assembling

 

the

 

hose

 

to

 

the

 

product

 

ensure

 

the

 

hose

 

ferrule

 

has

 

been

 

crimped

 

(as

 

highlighted)

 

on

 

both

 

ends

 

of

 

the

 

hose

 

after

 

the

 

braided

 

hose

 

sleeve.

 

 

 

 

 

Both

 

ends

 

of

 

the

 

hose

 

must

 

have

 

a

 

minimum

 

50mm

 

straight

 

section

 

before

 

any

 

bend.

 

50mmØ

 

Installation:

 

 

1.

 

Locate

 

base

 

plinth

 

(B)

 

onto

 

the

 

fine

 

threaded

 

side

 

located

 

on

 

top

 

of

 

fixing

 

column

 

(D).

  

 

2.

 

Place

 

upper

 

seal

 

(C)

 

under

 

the

 

recess

 

in

 

base

 

plinth

 

(B).

  

 

3.

 

Screw

 

both

 

the

 

base

 

plinth

 

(B),

 

upper

 

seal

 

(C)

 

and

 

fixing

 

column

 

(D)

 

into

 

the

 

mixer

 

body

 

(A

 

and

 

over

 

pull

out

 

hose

 

(M)),

 

we

 

recommend

 

gloves

 

as

 

the

 

thread

 

may

 

have

 

sharp

 

edges.

 

 

4.

 

Screw

 

the

 

hot

 

flexible

 

hose

 

(I)

 

and

 

cold

 

flexible

 

hose

 

(J)

 

into

 

mixer

 

body

 

(A)

 

hand

 

tight,

 

refer

 

to

 

figure

 

1

 

for

 

the

 

correct

 

inlets

 

shown

 

as

 

“H”

 

&

 

“C”.

 

 

5.

 

Screw

 

the

 

mixed

 

water

 

outlet

 

extension

 

(K)

 

into

 

the

 

mixed

 

water

 

outlet

 

“M”

 

as

 

shown

 

on

 

figure

 

1.

 

If

 

using

 

a

 

spanner

 

to

 

tighten

 

extension

 

(K)

 

do

 

not

 

overtighten

 

it

 

as

 

you

 

may

 

damage

 

the

 

seal

 

on

 

the

 

top

 

of

 

the

 

extension.

 

 

6.

 

Place

 

the

 

mixer

 

tap

 

(A),

 

with

 

base

 

plinth

 

(B),

 

upper

 

seal

 

(C)

 

and

 

fixing

 

column

 

(D)

 

onto

 

the

 

sink/worktop,

 

passing

 

the

 

flexible

 

hoses

 

(I&J),

 

mixed

 

water

 

outlet

 

(K)

 

and

 

the

 

pull

out

 

hose

 

(M)

 

through

 

the

 

tap

 

hole.

   

 

7.

 

Pass

 

the

 

lower

 

gasket

 

(F),

 

the

 

metal

 

spacer

 

(G)

 

and

 

fixing

 

nut

 

(H)

 

over

 

the

 

fixing

 

column

 

(D),

 

flexible

 

hoses

 

(I,

 

J

 

&

 

M))

 

and

 

mixed

 

water

 

outlet

 

(K).

 

Only

 

If

 

fitting

 

the

 

tap

 

to

 

a

 

stainless

steel

 

sink,

 

the

 

white

 

triangular

 

stabiliser

 

(E)

 

can

 

be

 

optionally

 

placed

 

where

 

shown

 

to

 

help

 

stabilise

 

the

 

weight

 

of

 

the

 

tap.

 

 

8.

 

With

 

the

 

tap

 

central

 

to

 

the

 

tap

 

hole

 

hold

 

it

 

securely

 

in

 

place

 

whilst

 

fastening

 

fixing

 

nut

 

(H)

 

securely

 

onto

 

the

 

fixing

 

column

 

(D)

 

to

 

fix

 

the

 

tap

 

(A)

 

into

 

its

 

correct

 

location.

 

 

9.

 

Fully

 

screw

 

the

 

pull

out

 

hose

 

(M)

 

into

 

the

 

mixer

 

water

 

outlet

 

extension

 

(K)

 

using

 

a

 

small

 

spanner

 

ensuring

 

the

 

seal

 

(L)

 

is

 

in

 

place

 

between

 

the

 

connection.

 

   

10.

 

Fix

 

the

 

hose

 

weight

 

(N)

 

with

 

screws

 

(O)

 

as

 

shown,

 

it

 

should

 

be

 

positioned

 

at

 

the

 

lowest

 

vertical

 

point

 

on

 

hose

 

(M)

 

as

 

the

 

hose

 

returns

 

upwards

 

to

 

the

 

tap

 

body

 

(A).

 

 

11.

 

Connect

 

the

 

hot

 

and

 

cold

 

flexible

 

hoses

 

(I

 

&

 

J)

 

to

 

the

 

water

 

mains

 

using

 

½”

 

BSPx15mm

 

compression

 

fittings.

 

Note:

 

Non

return

 

valves

 

will

 

be

 

pre

inserted

 

into

 

flexible

 

hoses

 

(I

 

&

 

J).

 

 

 

After

 

Installation:

 

 

Once

 

you

 

have

 

visually

 

checked

 

the

 

new

 

fittings

 

and

 

connections,

 

ensure

 

that

 

all

 

taps

 

and

 

drains

 

are

 

closed

 

except

 

the

 

new

 

product

 

which

 

should

 

be

 

left

 

open

.

 

Turn

 

on

 

(reconnect)

 

the

 

water

 

supplies,

 

check

 

carefully

 

for

 

leaks

 

around

 

the

 

installation

 

and

 

product

 

function.

 

Once

 

you

 

are

 

sure

 

of

 

no

 

leaks,

 

close

 

the

 

new

 

product

 

and

 

recheck

 

for

 

leaks,

 

turn

 

on

 

the

 

water

 

heating

 

power.

 

Clean

 

and

 

dry

 

the

 

product

 

of

 

any

 

marks

 

from

 

installation

 

then

 

cover

 

the

 

product

 

with

 

the

 

bag

 

provided

 

to

 

protect

 

it

 

until

 

use.

 

 

Important

 

Technical

 

Data

 

 

Minimum

 

operating

 

pressure:

 

1.25

 

bar

 

Maximum

 

operating

 

pressure:

 

5.5

 

bar*

 

Flow

 

characteristics:

 

Single

 

flow

 

Maximum

 

hot

 

water

 

temperature

:

 

60°C*

 

Recommended

 

hot

 

water

 

temperature:

 

46°C

 

 

*If

 

these

 

temperatures

 

or

 

pressures

 

are

 

exceeded,

 

even

 

for

 

short

 

periods,

 

damage

 

can

 

result

 

and

 

will

 

void

 

your

 

warranty.

 

In

 

these

 

instances,

 

reduce

 

the

 

incoming

 

water

 

temperature

 

and

 

or

 

install

 

a

 

pressure

 

reducing

 

valve.

 

Ensure

 

that

 

your

 

Abode

 

product

 

is

 

fitted

 

in

 

accordance

 

with

 

Local

 

Water

 

Byelaws

 

or

 

regulations

 

by

 

a

 

qualified

 

installer.

 

These

 

installation

 

guidelines

 

have

 

been

 

prepared

 

for

 

your

 

direction

 

and

 

you

 

must

 

exercise

 

due

 

care

 

at

 

all

 

times.

 

We

 

do

 

not

 

accept

 

responsibility

 

for

 

problems

 

that

 

may

 

occur

 

through

 

improper

 

installation.

 

Whilst

 

installing

 

the

 

product

 

take

 

care

 

not

 

to

 

accidentally

 

loosen

 

any

 

screwed

 

assemblies.

 

Manufacturers

 

Product

 

Reference:

 

AT2190,

 

AT2191,

 

&

 

AT2192

 

©Abode

 ‐ 

03/2023

 

 

 

 

 

 

Unit

 

L,

 

Zenith

 

Park,

 

Whaley

 

Road,

 

Barnsley,

 

S75

 

1HT

 

Tel:

 

(+44)

 

01226

 

283434

 

or

 

www.abodedesigns.co.uk

 

 

All

 

errors

 

and

 

omissions

 

excepted.

 

 

Reviews: