background image

Parts and Contents: 

 

Key 

Description 

Qty 

 

Mixertap  

Rubber seals 

Cold and hot water inlets 
(with integral check valves) 

Base plinths 

Upper sink seals 

Lower sink seals 

Fixing nuts 

 

Installation Instructions: 
Preparation 

 

Before installing the new product it is essential that you thoroughly flush through the supply pipes in order to remove any 
remaining solder, swarf or impurities from your system

. Failure to carry out this simple procedure could cause problems or 

damage to the workings of the product or reduce performance invalidating the warranty. 
 
We strongly recommend best practice of installing particle filters and isolation valves to both the hot and cold feed pipes in an 
accessible position. This will help to prevent premature failure of the valves and ease any future maintenance. 
 

All parts should be removed from their packaging and inspected for any transport damage prior to installation.

 

 
Shut off (isolate) your hot and cold water supply locally at the point of installation before continuing with the installation. If the 
water cannot be isolated locally the turn off the mains stopcock and power to any heating system, now open the lowest tap or 
drain point in the system until both hot and cold supplies are fully drained. 
 
This product requires a 35mm

 tap hole, if replacing an existing product, remove it and clean the end of the hot and cold feed 

pipes using wire wool, the tap hole area should be free from dirt and sealant.  
If the handles on the product operate backwards and forwards, allow for this when planning the sink or tap hole position. 
Loosely position the product and fittings to check if any alteration to the existing pipework is required, if needed, do this now. 
If the product is single flow (see section important technical data “flow characteristics”) then non return (check) valves must be 
installed to comply with regulations. Some products are supplied with non-return valves this will be noted in the instructions. 

    

Correct use of Flexible Hose Connectors

 

 
If this product is supplied with flexible hose connections for ease of installation you must observe the conditions below,  
failure to observe these standard installation guidelines will invalidate the warranty for your product. 

 

 

   

 

 

Always 

screw 

the flexi hoses 
into the 
product only 
by hand,

 until 

feeling 
mechanical 
rest, 

a spanner 

must not be 
used on the 
product end of 
the connecting 
hose. 

 
Always use the 
pipes provided 
and not an 
alternative 
substitute 

 

The braiding 
on the flexible 
hose 

must not 

be in contact 
with anything 
else, for 
example 
chemicals, 
internal or 
external room 
walls or 
dissimilar 
metals or 
materials or 
sharp objects.

 

 

 

          

 

Never twist or 
stretch the 
flexible hose

 

during 
installation. 
 

Do not 
overtighten

 the 

hexagonal end 
of the hose 
connecting to 
the supply 
feeds when 
using a spanner 
causing the 
hose to twist. 

 

 

 

 

Hoses must 
not be double 
bent

 in 

multiple 
directions

 

kinked or 
looped

.  

 

Observe the 
minimum 
bend radius of 
50mm.

 

 

 
 

 

 
Before 
assembling

 the 

hose to the 
product 

ensure 

the hose 
ferrule has 
been crimped

 

(as highlighted) 
on both ends of 
the hose after 
the braided 
hose sleeve. 

 

 

 

 

Both ends

 of 

the hose must 
have a 

minimum 
50mm 
straight 
section

 before 

any bend. 

50mmØ 