18
5.
System
Specifications
Model
ATS-120
ATS-130
ATS-216
ATS-232
Input
Input voltage
100/110/115/120/127
( +/- 5% / 10% / 15% / 20% )
200/208/220/230/240
( +/- 5% / 10% / 15% / 20% )
Input voltage range
75Vac~150Vac
150Vac~300Vac
Input frequency
50 / 60Hz
( +/- 5% / 10% / 15% / 20% )
Input current
20A
30A
16A
32A
Output
Output voltage
100/110/115/120/127
200/208/220/230/240
Output current
20A
30A
16A
32A
Protection
Input Breaker(option)
Electronic circuit
Communication
RS-232, USB, Dry contact
external slot for option card(SNMP, RS-485)
Transfer time(ms)
8~12ms (Typical)
*
Efficiency
99%(with full linear load)
Display
LCD+LED
Connection
Input
NEMA 5-20 x 2 NEMA L5-30 x 2
IEC C20 x 2
Terminal Block 6P
output
NEMA 5-20 x 8
NEMA L5-30R x 1
NEMA 5-20x 8
IEC C19 x 1
IEC C13 x 8
IEC C19 x 2
IEC C13 x 16
Physical
Dimension,
D X W X H (mm)
275x440x44 275x440x88 275x440x44 275x440x88
Net Weight (kgs)
4
6
4
6
Environment
Operating
temperature
-5~40
∘
C @ 0~90% RH(non-condensing)
Standards
compliance
Safety
UL 60950-1/ CAN/CSA C22.2 No. 60950-1 /
IEC 60950-1
EMC
FCC Part 15 / EN62310-2