FRONT PANEL EXPLANATIONS

 

 

REAR PANEL EXPLANATIONS

 

 

1. Line LED (

): 

Green LED remains standstill when Utility is normal.   
Green LED flashes every 3 seconds and 

simultaneously buzzer alarms continuously when 
Utility failure. 

Green LED flashes every 3 seconds when the UPS is 

in Battery charging mode, and flashes every 0.5 
seconds and buzzer alarms every 0.5 seconds in 
battery low condition. 

Green LED remains standstill and simultaneously 

buzzer alarms continuously when the UPS is in 
overload condition. 

2. Check Battery LED (

): 

Red LED remains standstill when the Battery is failure. 

3. Main Switch: 

a. To Control on/off the UPS when Utility is normal. 
b. To enable “DC-Start” Function when Utility fails. (To enable DC Start 

properly, you are recommended to connect <80% output load with the UPS 
only) 

P.S. Make sure the computer connected to the UPS is switched on before 
enable the "DC-Start" function. You are not recommended to add some other 
computer or peripherals after DC-Start function is activated.

 

1. AC Inlet 
2. Backup Outlets: 2pcs NEMA5-15R 
3. Computer Interface: USB communication port. 
4. 

RJ11/RJ45 connector

 

5. Site Wiring Fault Indicator: 
6. AC Circuit Breaker. (625/8A, 525/7A) 
7. Bypass Outlets: 2pcs NEMA5-15R 

 

REPLACING THE BATTERY 

 

Note: Once the battery is disconnected, 
the loads are not protected from power 
outages. 

1.  Use a cross-type screwdriver to remove the 

two front panel screws and slide down the 
panel. 

2.  Gently Pull the battery out of the UPS. 
3.  Loosen the black wire from the negative (-) 

terminal and red wire from the positive (+) 
terminal. 

4.  Connect the battery leads to the new battery.
5.  Note: Small sparks at the battery connectors 

are normal during connection. 

6.  Slide the battery into the UPS. 
7.  Close the front panel and fasten two screws.
8.  Dispose of the old battery properly at an 

appropriate recycling facility. 

 

 

TROUBLE SHOOTING

 

When your UPS malfunctions during operation, you may check the list below for proper adjustment. If the adjustment still be in vain, 
please contact your sales agent for help.   

Situation Check 

Items  Solution 

Mains normal but 'Line'

 

LED is not on. 

1. Is the power switch on? 
2. Is the fuse in order? 
3. Is the power cord loose? 

1. .Press Main Switch on. 
2. Change fuse w/same rating. 
3. Re-connect the power cord properly. 

'Line' LED flashes every second but no 
output 

Battery voltage is too low 

Recharge the UPS for 24 hours.   

Alarm buzzer beeps continuously when 
Utility is normal.   

Check to see load status if it is in overload. 

Remove some uncritical load. 

Alarm buzzer beeps for 10 seconds, then 
the UPS is turned off 

 

Remove some uncritical load and re-switch 
on the UPS.   

No LEDs display on the front panel 

 

Consult with your sales agent For help. 

UPS dose not provide expected back up 
time. 

1. The UPS’s battery is weak due to recent 

outage. 

2. The UPS’s battery is near the end of its 

service life. 

1. Charge the battery. 
2. If the battery is near the end of its service 

lift, consider replacing the battery. 

The UPS operates normally, but the site 
wiring fault indicator is lit. 

Building wiring error such as missing ground or 
hot to neutral wire reversal. 

Have a qualified electrician correct the 
building wiring. 

UPS switch on then connect Utility, but 
UPS is unable to work under Utility mode 

Is the Utility normal? 
 

If Utility is normal, connect Utility first then 
switch on UPS. 

 

3

4

5

2

7

1

6