Setup via the ABL User Interface application
|
23
Setup via the ABL User Interface application
Before you set up and commence initial operation of METERS | METERL, your charging system must first be correctly
addressed and completely set up. METERS | METERL can then be set up for operation with the charging system via
the
ABL User Interface
web-based application.
WARNING!
METERS | METERL can only be set up in a pre-configured charging system
Please note that the charging system must first be fully and properly configured before you can set up load man-
agement via METERS | METERL. The corresponding installation manual describes in detail how to configure a
single charging station or charging group with controller and extender charging stations.
NOTE
Updating the application
The working steps described below refer to the current version of the
ABL User Interface
application.
Please check in advance which version is installed on your system and carry out an update in any case.
The instructions included in the installation package describe step by step how to perform the update.
The application offers a role-based concept that restricts the editing of selected parameters.
Owner
The
Owner
may view all information about the application and the installed charging stations,
perform updates and set up data communication in the system.
Installer
The
Installer
makes fundamental changes to the system properties.
This person must therefore be a qualified electrician, who, on the basis of their specialist
training and experience, as well as their knowledge of the relevant regulations, can assess
and carry out the working steps described in this manual and recognise potential hazards.
WARNING!
Registration as a qualified electrician required
The working steps described below for setting up the system must be carried out in the
Installer
role.
Contact a qualified specialist electrical contractor if the following working steps need to be carried out.
Proceed as follows:
1
Switch on the Controller charging station / control
unit.
y
Always wait for two minutes until the SBC has
completed set-up.
I