www.ablmobility.de
Albert-Büttner-Straße 11
D-91207 Lauf / Pegnitz
Phone +49 (0) 9123 188-0
Fax +49 (0) 9123 188-188
ABL SURSUM
Bayerische Elektrozubehör GmbH & Co. KG
3
In case of connection errors, check the network settings of the computer and adjust them as follows:
• Network: 169.254.0.0
• Subnet mask:
255.255.0.0
• Address: 169.254.1.2
3
The online administration interface opens in the browser. The following functions are available using the tabs:
Tab
Description
Overview
• Checking the status of all recognised master and slave model variants
• Checking the system software version
Configuration
• Checking information about the 1V0002 control unit, the backend and OCPP
• Editing backend operator details (only when changing backend operator)
• Assigning backend ID to control unit
Devices
• Checking the system's total connected load
• Checking the maximum connected load for each Slave wallbox
Products
• Registering additional Slave wallboxes in the system
• Editing 1V0002 properties
Certificates
• Checking backend operator certificates
Diagnostic
Functions
• Checking version and status information for all communicating components in the
system
Logs
• Checking logged access to the communicating components in the system
Maintenance
• Carrying out a restart (software and/or hardware)
• Updating the system software
• Running system diagnostics
4
Disconnect the Ethernet cable from the RJ45 sockets in both the 1V0002 and the computer.
The 1V0002 control unit is now configured as master to control the Slave wallboxes.
Subject to change: All performance characteristics, technical and other specifications are subject to change without prior notice.
All manuals and user guides at all-guides.com