In case of connection errors, check the network settings of the computer and adjust them as follows:

•  Network:   169.254.0.0
•  Subnet mask: 

 

255.255.0.0

•  Address:  169.254.1.2

The online administration interface opens in the browser. The following functions are available using the tabs:

Tab

 

Description

Overview

•  Checking the status of all recognised master and slave model variants
•  Checking the system software version

Configuration

•  Checking information about the 1V0002 control unit, the backend and OCPP
•  Editing backend operator details (only when changing backend operator)
•  Assigning backend ID to control unit

Devices

•  Checking the system's total connected load
•  Checking the maximum connected load for each Slave wallbox

Products

•  Registering additional Slave wallboxes in the system
•  Editing 1V0002 properties

Certificates

•  Checking backend operator certificates

Diagnostic 

Functions

•  Checking version and status information for all communicating components in the 

system

Logs

•  Checking logged access to the communicating components in the system

Maintenance

•  Carrying out a restart (software and/or hardware)
•  Updating the system software
•  Running system diagnostics

Disconnect the Ethernet cable from the RJ45 sockets in both the 1V0002 and the computer. 

The 1V0002 control unit is now configured as master to control the Slave wallboxes.

Subject to change: All performance characteristics, technical and other specifications are subject to change without prior notice.

All manuals and user guides at all-guides.com

Summary of Contents for 1V0002

Page 1: ...tractor Mechanical and electrical installation During the installation the circuit breaker for the supply line must be switched off in the house distribution Tools and materials required Pozidriv screwdriver wire stripper crimping tool 1 Attach the 1V0002 control unit using the DIN rail at the chosen installation site 2 Strip the wires of the supply line put ferrules on the wires and crimp on the ...

Page 2: ...ble into the first Slave wallbox and clamp in onto the left or right hand side terminal block of its daisy chain circuit board see the detailed installation and operating manual for the wallbox For correct functioning the colour coding between the individual data cable wire strands and the daisy chain terminal blocks must be strictly observed in all master slave units Only the first Slave wallbox ...

Page 3: ...r Assigning backend ID to control unit Devices Checking the system s total connected load Checking the maximum connected load for each Slave wallbox Products Registering additional Slave wallboxes in the system Editing 1V0002 properties Certificates Checking backend operator certificates Diagnostic Functions Checking version and status information for all communicating components in the system Log...

Page 4: ...abl de www ablmobility de Albert Büttner Straße 11 D 91207 Lauf Pegnitz Phone 49 0 9123 188 0 Fax 49 0 9123 188 188 ABL SURSUM Bayerische Elektrozubehör GmbH Co KG All manuals and user guides at all guides com ...

Reviews: