EN
-
10
4 Product description
xFUME™ ADVANCED HP 230V – CSA
4.2 Control elements and connections
Fig. 3
Control elements/ports
A
Service LED
B
Operation LED
C
Power LED
D
Hour meter
E
<Auto/Manual> switch
F
<On/Off> switch
G
Mains connecting cable
H
Speed controller
I
Fuse
J
Current clamp port 1
K
Current clamp port 2
<Auto/Manual> switch (E)
The automatic starting function is activated when the switch is set to
<Auto>. If the switch is set to <Manual>, the automatic starting function is
inactive and the device must be switched on and off manually.
Service LED (A)
The device is equipped with a safety device to monitor the minimum air
volume flow to be extracted. A differential pressure switch is used for
monitoring purposes. The service LED illuminates in continuously when
both filter cartridges are not functioning properly or are saturated and
must be replaced. During initialization, the service LED and the power
LED flash alternately.
Operation LED (B)
The operation LED illuminates continuously when the motor is running.
During initialization, the power LED and the service LED flash alternately.
Power LED (C)
The power LED illuminates continuously if the device has been switched
on by the <On/Off> switch.
A
G
B
C
D
E
F
H
I
J
K