![background image](http://html1.mh-extra.com/html/abicor-binzel/wk43/wk43_operating-instructions-manual_3406399030.webp)
EN - 10
5 Functional Description
Coolant recirculator
4.1 Transport
The components are carefully checked and packaged, however damage may
occur during shipping.
4.2 Storage
Physical storage conditions in a closed environment:
Tab. 2 Ambient conditions for shipment and storage on page EN-6
5 Functional Description
The
Coolant recirculator
is used for cooling in case of liquid-cooled
devices. Preferably used with liquid-cooled welding and cutting torches. The
submergible pump
delivers the coolant from the tank
exchanger
to the coolant supply connection (blue)
.
The coolant (red)
flows directly back to the tank
.
Goods-in inspection
Use the delivery note to check that everything has been delivered.
Check the delivery for damage (visual inspection).
In case of complaints
If the delivery has been damaged during transportation, contact the last
carrier immediately. Retain the packaging for potential inspection by the
carrier.
Packaging for returns
Where possible, use the original packaging and the original packaging
material. If you have any questions about the packaging and/or how to
secure an item during shipment, please consult your supplier.
Tab. 8
Transport
1
Heat exchanger
(finned radiator), 2-row
2
Coolant supply (blue)
3
Coolant return (red)
4
Tank
5
Motor with fan
6
Submergible pump
Fig. 4
Circuit diagram WK23 with flow control option
1
6
2
3
4
5