4 Commissioning
SR/ABITIG
®
GRIP
4 Commissioning
4.1 Equipping the torch
Equip the torch neck according to the following figure:
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to for the entire duration of
maintenance, servicing, mounting, dismounting and repair work:
• Switch off the power source.
• Close the gas supply.
• Disconnect the mains plug.
NOTICE
• The commissioning may only be carriedout by authorized personnel
(in Germany see TRBS 1203).
CAUTION
Risk of injury
Through-hole or puncture caused by sharpened electrode.
• Do not reach into the danger zone.
• Wear protective gloves.
1
Torch body
2
Gas nozzle
3
Tungsten electrode
4
Torch cap
5
Collet body
Fig. 1
Equipping the torch
Step 1
Step 2-3
Step 4
1
5
3
4
2