
MF1-Laser Front/Rear
6 Commissioning
EN - 19
6.3.3 Slippage check
Position the wire protruding from the feeding body approx. 50 mm above of a suitable object at an exit
angle of approx. 45 degrees.
Fig. 16 Slippage check on page EN-19
Feed the wire against this resistance and check if slippage occurs.
If slippage occurs, the contact pressure must be increased.
1
Feeding body
2
Wire protruding from feeding
body
3
Wire
Fig. 16
Slippage check
1
2
3