6 Commissioning
iROB Feed HA
6.2.2 Connecting the torch
Connect the cables and lines to the front side as shown in the following figure:
1
Connect the torch’s red hose to the connector for the coolant return
.
2
Connect the torch’s blue hose to the connector for the coolant supply
3
Connect the MIG torch to the corresponding connector
. The screw lock must be screwed on tightly.
6.2.3 Wire feeder
1
Connection for external devices (push-pull) (optional)
2
Connection for external devices (RC) (optional)
3
Connection for external start
4
Coolant supply
5
Coolant return
6
Connection for MIG torch
Fig. 4
Connection for MIG/MAG welding, front side
1
2
3
4
5
6
CAUTION
Risk of injury
Puncture or cut-in wounds may be caused by the wire electrode.
• Keep your hands out of the danger zone.
• Wear the correct protective gloves.
CAUTION
Risk of injury
Physical injury caused by the start of the wire.
• Keep process-side drive away from the body.
CAUTION
Risk of injury
The discharged wire can cause serious injuries to the hands, face and eyes.
• Maintain sufficient distance between your head and the MIG/MAG torch when the wire is inserted and fed.