7 Operation
iROB
®
501 PRO
7.2 Administrative settings
7.2.1 Password-protecting the welding parameters
Activating this function protects against the following operating errors on the welding power source control
panel:
— Changing the welding parameters (it is still possible to check the settings)
— Operating the <Parameter selection> button and the <Parameter setting> knob
If the password function is activated, it remains active even after the device is switched on again via internal
functions.
Assigning a password
The password must be a three-digit number. "000" is not accepted as a password.
► Make a note of the password and keep it in a safe place.
A forgotten password can only be reset by ABICOR BINZEL.
► To cancel password setting, set the main switch to <0>.
Activating password protection
1
Set the main switch to <0>.
2
Press and hold the <Function> and <Enter> buttons
simultaneously and set the main switch back to <I>.
Keep both buttons pressed until <PAS → Loc> are
displayed alternately in the left digital display.
3
Release the buttons when <Loc> is displayed.
If a password has not yet been assigned, <Loc> is displayed.
Continue with step
If a password has already been assigned, <Loc> flashes.
Continue with step
4
To change the password, first enter the old password as
described below and press <Enter>.
If the number matches the stored password, both digital
displays show <good>. The new password can be entered
as described below.
5
Set the hundreds digit with the <Parameter setting> knob.
6
Press the <Parameter selection> button.
The tens digit starts to flash.
7
Set the tens and ones digits in the same way with the
<Parameter setting> knob.
8
Check the password and press <Enter> twice.
The password is saved.
F
+
A
m/min.
sec.
Hz
±
V
%
JOB.No.
A
m/min.
sec.
Hz
±
V
%
JOB.No.
+
1
Press and hold <Enter> for more than 3 seconds.
Password protection is active.