6 Putting into operation
FEC W3
6.3 Current clamp (optional)
If welding conditions are not favourable, a current clamp instead of an earth cable may be used. This is connected to the
FEC W3
via the 4-pole plug and routed above the earth cable and cable assembly as required. When the welding process
starts, the
FEC W3
receives a signal and starts the extraction process.
1
Connect the current clamp plug to the current clamp socket
2
Route the current clamp above the earth cable or the cable assembly.
3
Press the A/Auto
button on the control panel.
The extraction process starts as soon as you start the welding process.
1
A/Auto button
2
Motor protective switch
3
Power cable connector
4
Socket for current clamp (optional)
Fig. 7
Current clamp
1
Current clamp
2
Red dot
3
Cable assembly
Fig. 8
Current clamp above cable assembly
NOTICE
• It is imperative that you ensure that the red dot on the current clamp is always pointing in the direction of the current
flow.
1
2
3
4
1
2
3
Summary of Contents for FEC W3
Page 31: ...FEC W3 13 Anhang BAL 0675 0 2019 09 16 DE 31 Abb 18 Elektroschaltplan 230 V 50 Hz...
Page 32: ...DE 32 BAL 0675 0 2019 09 16 13 Anhang FEC W3 Abb 19 Elektroschaltplan 120 V 50 60 Hz...
Page 33: ...FEC W3 13 Anhang BAL 0675 0 2019 09 16 DE 33 Abb 20 Elektroschaltplan 120 V 50 60 Hz...
Page 63: ...FEC W3 13 Appendix BAL 0675 0 2019 09 16 EN 31 Fig 18 Circuit diagram 230 V 50 Hz...
Page 64: ...EN 32 BAL 0675 0 2019 09 16 13 Appendix FEC W3 Fig 19 Circuit diagram 120 V 50 60 Hz...
Page 65: ...FEC W3 13 Appendix BAL 0675 0 2019 09 16 EN 33 Fig 20 Circuit diagram 120 V 50 60 Hz...
Page 95: ...FEC W3 13 Annexe BAL 0675 0 2019 09 16 FR 31 Fig 18 Sch ma de connexion lectrique 230 V 50 Hz...