Abicor Binzel CT-1000 Instruction Manual Download Page 4

Safety 

 

Before using make sure all operators are familiar with the welding process and have had appropriate 
training relating to the risks involved. 
 
The Health and Safety Executive publish good info regarding this, please see www.hse.gov.uk/weld-
ing/other-welding-risks.htm 
 
When welding or cutting in an environment with increased risk of electric shock extra precautions 
must be observed. Typical conditions with increased risk of electric shock are working in wet or 
damp conditions, working inside vessels, working in cramped conditions and exposed to conductive 
parts, etc. DO NOT TAKE ANY RISKS 
 
This water cooler must be used upright. It must be placed in a stable position to ensure it cannot 
topple over. If the cooler topples over there is a risk of electric shock. Wherever possible this unit 
should be fixed into position. There are 4 x M5 female threads on the underside of the cooler inside 
the rubber feet for mounting purposes. If using these take care not to obstruct the air flow under the 
cooler, it needs at least 35mm from the underside grills to any other objects & a minimum of 100mm 
from the side fan grill to anything else.  
 
This cooler is designed for use indoors and must not be used in the rain or a wet environment. 
 
This cooler has a splash proof on/off switch fitted which is designed to duct away any water 
splashes from the internal electrics to prevent electric shock, however in the event of a large fluid 
spill directly over the switch the cooler should be checked by a competent person for safety before 
using again.

 

Declaration of conformity 

 
This equipment is manufactured to comply with 2006/95/EEC, BS EN 60974-2 
This equipment is manufactured to comply with 89/336/EEC, BS EN 60974-10 
This equipment is manufactured to RoHS directive 2006/95/EU 

 
 
 
 
 

Date 3/11/2014 
 
R P Rycroft

R Rycroft 

Technical Arc Ltd

York UK 

Technical Specifications 

 

Model CT-1000                                                           110V                    230V

 

                                                                                                                                  

Supply volts (U1) +/-10%                                                                             110V/115V 50HZ            230V 50HZ

 

Input current (I1max)                                                                                    2.0 Amps                        1.0 Amps

 

Fuse size (slow blow)                                                                                   3 A                                  1.25 A 
Pressure max (pmax)                                                                                   3.3 bar                            3.3 bar 
Max flow rate Litres/min                                                                               10                                   10 
Typical operating flow rate                                                                           2                                     2 
Cooling capacity@25C amb@20 rise                                                          1000W                            1000W

 

Cooling capacity@25C amb@40C rise                                                       2000W                            2000W  
Maximum coolant temperature                                                                     70C                                70C

 

Total fluid capacity                                                                                        2.5 litres                         2.5 litres

 

Degree of protection                                                                                     IP21                                IP21

 