Safety
Before using make sure all operators are familiar with the welding process and have had appropriate
training relating to the risks involved.
The Health and Safety Executive publish good info regarding this, please see www.hse.gov.uk/weld-
ing/other-welding-risks.htm
When welding or cutting in an environment with increased risk of electric shock extra precautions
must be observed. Typical conditions with increased risk of electric shock are working in wet or
damp conditions, working inside vessels, working in cramped conditions and exposed to conductive
parts, etc. DO NOT TAKE ANY RISKS
This water cooler must be used upright. It must be placed in a stable position to ensure it cannot
topple over. If the cooler topples over there is a risk of electric shock. Wherever possible this unit
should be fixed into position. There are 4 x M5 female threads on the underside of the cooler inside
the rubber feet for mounting purposes. If using these take care not to obstruct the air flow under the
cooler, it needs at least 35mm from the underside grills to any other objects & a minimum of 100mm
from the side fan grill to anything else.
This cooler is designed for use indoors and must not be used in the rain or a wet environment.
This cooler has a splash proof on/off switch fitted which is designed to duct away any water
splashes from the internal electrics to prevent electric shock, however in the event of a large fluid
spill directly over the switch the cooler should be checked by a competent person for safety before
using again.
Declaration of conformity
This equipment is manufactured to comply with 2006/95/EEC, BS EN 60974-2
This equipment is manufactured to comply with 89/336/EEC, BS EN 60974-10
This equipment is manufactured to RoHS directive 2006/95/EU
Date 3/11/2014
R P Rycroft
R Rycroft
Technical Arc Ltd
York UK
Technical Specifications
Model CT-1000 110V 230V
Supply volts (U1) +/-10% 110V/115V 50HZ 230V 50HZ
Input current (I1max) 2.0 Amps 1.0 Amps
Fuse size (slow blow) 3 A 1.25 A
Pressure max (pmax) 3.3 bar 3.3 bar
Max flow rate Litres/min 10 10
Typical operating flow rate 2 2
Cooling capacity@25C amb@20 rise 1000W 1000W
Cooling capacity@25C amb@40C rise 2000W 2000W
Maximum coolant temperature 70C 70C
Total fluid capacity 2.5 litres 2.5 litres
Degree of protection IP21 IP21
Summary of Contents for CT-1000
Page 2: ......
Page 7: ......
Page 8: ...CT 1000 LIQUID COOLING SYSTEM EXCLUSIVELY FOR MADE IN BRITAIN...