6.10 Connecting the pneumatic system
For the supply line, a compressed air hose with an inner width of min.
ø
6mm is necessary which is inserted
into the angle screw connection at the housing of the cleaning station. A shut-off valve in the supply line is
recommended. This allows the BRS-CCi to be quickly and simply depressurized in order to carry out any
installation and maintenance work.
7 Operation
1
Switch on the robot control.
2
Start the welding process.
3
Stop the welding process.
8 Putting out of operation
1
Switch off the robot control.
9 Maintenance and cleaning
Regular and lasting maintenance and cleaning are the prerequisite of a long life and a trouble-free function.
In doing so, observe the following:
Fig. 12
Connecting the pneumatic system
S1
M
M
S4
Z2
Z1
5
3
1
14
4 2
12
14
5 3
1
12
14
4
2
12
14
5 3
1
12
14
4
2
12
14
12
12
Z3
E
P
V
Compressed air of motor
Clamping cylinder Lifting cylinder
Injector
Shear
unscrew clamp
bottom top
open closed
D8/d6
D6/d4
D8/d6 D6/d4
D6/d4
D6/d4
Y2
Y1
Y4
Y3
6 bar
Drawing from th
bottle
D6/d4
6x1
NOTE
• As the cleaning station BRS-CCi is integrated into a welding system, the operating instructions of the
welding components, such as welding torch and robot control, must be observed during operation.
• Make sure that the cleaning station BRS-CCi is operated with a front sheet only.
NOTE
• As the cleaning station BRS-CCi is integrated into a welding system, putting out of operation depends
on the robot control. Please make sure that the shutdown procedures for all components mounted in
the welding system are strictly observed.