EN - 6
BAL.0186 • 2019-06-19
3 Product description
ABITIG
®
Little
*According to EN 60 974-7 the value for alternating current (AC) must be given at 70% of the
tested direct current value (DC).
All data refer to 4 m cable assemblies. For any further information regarding the available
cable assembly designs and performance data, please refer to the current order
documentation.
3.2 Signs and symbols used
The following signs and symbols are used in the operating instructions:
Type
Type of
cooling
Load
ED
Electrode
Gas flow Cooling
Torch inlet
pressure
ABITIG
®
Little
DC
AC*
Max. supply
temp.
Min.
flow
min.
max.
A
A
%
mm
l/min
°C
l/min
bar
bar
9
air
110
80
35
0.5 - 1.6
5 - 12
17
air
140
100
35
0.5 - 2.4
7 - 15
90
air
90
60
35
1.0 - 2.4
5 - 12
150
air
140
100
35
1.0 - 2.4
5 - 12
24 G
air
110
80
35
0.5 - 1.6
5 - 12
20
liquid
220 150
100 0.5 -- 3.2
8 - 22
50
0.7
2.5
3.5
25
liquid
200 140
100 0.5 -- 3.2
8 - 22
50
0.7
2.5
3.5
180W
liquid
180
130
100 1.0 - 3.2
7 - 18
50
0,7
2.5
3.5
260 W
liquid
240
170
100 1.0 - 3.2
7 - 18
50
0.7
2.5
3.5
24 W
liquid
140
100
100 0.5 - 2.4
7 - 15
50
0.7
2.5
3.5
Tab. 4
Product-specific torch data (EN 60 974-7)
Liquid-cooled torches
min. 800 W
Tab. 5
Required cooling unit capacity
Symbol
Description
•
Bullet symbol for instructions and lists
Cross reference symbol refers to detailed, supplementary or further information
1
Step(s) described in the text to be carried out in succession