EN
-
18
6 Putting into operation
ABICAR ADVANCED 42V
6.8 Testing the function
Proceed as follows to test whether the device is correctly connected:
► Insert the connection cable, switch on the power source, switch on the device, and set the welding start
signal switch to “Test”.
Fig. 3 Operating panel on page EN
The arc will ignite for a split second.
6.9 Mounting flexible guide rails (optional)
WARNING
Stunning of eyes by arcs
Arcs produced when testing can damage your eyes.
► Check and wear your personal protective equipment (eye protection).
Required tool:
Internal hexagonal spanner AF3, AF4 and AF5
Allows movement on a surface and on tubes.
Max. rail length: 1.85 m
Min. bending radius: 1 m
1
Connect the flexible guide rails to the magnetic blocks
with a butt joint or lap joint.
2
Position magnets along the welding direction on the
workpiece.
3
Set the required distance on the adjustment tool.
4
Release the lever of the adjustment tool and place it on
the first magnet. Place the side of the stop pin against
the external edge of the material, or place the tip of
the stop pin in a groove.
5
Lock the lever of the adjustment tool.
6
Remove the remainder of the rail from the workpiece.
7
Move the adjustment tool along the guiding and
attach all magnets.
8
Disconnect standard guide arms from the device and
mount guide arms for flexible guide rails.
6.3 Positioning guide arms on page EN
9
Hang the device with the guide arms in the flexible
guide rails.