RHS07-316 Installation Guide
5. Slide base plate (A), over the protruding hot & cold water hoses (at this stage do not screw base plate (A) to the floor).
Note: The flow control should be inserted with the protruding side into the
showerhead, taking care not to cause and damage to the flow controller. In
accordance with AS/NZS3662 CI.6e. These showers may not be suitable for
use with gravity fed waterheaters, low and unequal pressure supply networks,
instantaneous water heaters, tempering valves and/or thermostatic mixing
valves. In accordance with AS/NZS3662CI.6c.
The following pressure range should be complied with:
·Minimum working pressure 150Kpa
·Maximum working pressure 750Kpa
ALL ABEY SHOWERS MUST BE INSTALLED IN ACCORDANCE WITH
AS/NZS3500 SERIES.
ALL ABEY SHOWERS ARE CERTIFIED IN ACCORDANCE WITH
AS/NZS 3662:2005, LICENCE NUMBER WM-022172.
1. Plumber to prepare the hot & cold-water supply hoses protruding 150 – 200m from the ground, with two x ½ inch threaded male connectors
(to connect to the shower hoses).
Note:
Check base plate (A) drawing for dimensions. The base plate should fit over top of the two male connectors
.
4. Using base plate (A), mark the locations of the 3 holes on the floor and drill hole sizes according to screw size being used.
6. Take the bottom of base pipe (B) and gently slide base cover (C) approximately 150mm up base pipe (B). Slide hot & cold hose through the pipe,
attach base pipe (B) to base plate (A).
2. Take the two long water hoses from the carton, hoses have a ½ inch threaded female connector. Connect the hot hose (red sheath) to the hot water
supply male connector. Connect the cold hose (blue sheath) to the cold water supply male connector.
3. Briefly turn on the water to test the functionality of the hoses, check for leaks and to verify both hot & cold hoses are running properly. If issues exist,
disconnect the water hoses and apply plumber’s tape or thread sealant to the threaded connection, then reconnect.
7. Take diverter/shower handle part (D), attach the male thread tops of the hot & cold hoses to the underside of part (D) to the female connectors inside.
Note:
Hot water hose is to be connected to the female connector with red tape surround. Cold water hose is to be connected to the female connector
with the blue tape surround.
8. Attach the diverter/shower handle part (D) to the base pipe (B) by screwing together.
Note:
Only twist base pipe (B).
9. Fix base plate (A) by tightening the screws through the base plate holes into the drilled holes in the ground. Slide base cover (C) over base pipe (B) to
cover base plate (A).
10. Install shower arm (E) on to the diverter (D), apply plumber’s tape or thread sealant to the threaded connection to prevent leaking.
11. Affix rain shower (F) to the shower arm (E) ensuring the flow control widget is fitted correctly between parts (F) and (E).
12. Attach the hand shower hose to the male connector on the diverter (D), attach the hand shower (G) to the shower hose, ensuring the flow control widget
is fitted correctly between them.
13. Once installation is complete, test the shower; on/off, hot/cold, rain shower/hand shower, to ensure all parts are running correctly and there are no leaks.
A
35mm
95mm
65mm
X
E
G
F
C
B
D