Abexo SH230 Manual Download Page 2

DECLARATION OF EU CONFORMITY

Product: SH230

Manufacturer: AB TECNO S.r.L. - Via Cicogna, 95 - 40068 San Lazzaro di Savena (BO)

The Manufacturer declares under its own responsibility that the product covered by the 

declaration meets all the provisions applicable in the following Directives:

2014/35/EU - on the harmonization of the laws of the Member States relating to the making 

available on the market of electrical equipment intended for use within certain voltage 

limits.

2014/30/EU - for the harmonization of the laws of the Member States relating to electro-

magnetic compatibility and complies with the relevant harmonization legislation of the 

Union: CEI EN 60947-1: 2008/A1: 2012/A2: 2015, CEI EN 60947-5-1: 2005/A1: 2010
Bologna, lì 01/02/2018 

 

 

 

                 AB TECNO's CEO

        

 

Ulisse 

Pagani

As required by the Directive 2012/19/CE concerning the Waste of Electronic and 

Electrical Equipment (WEEE) it is necessary: to not dispose of WEEE as municipal 

mixed waste and make a separate collection of such WEEE; contact your municipa-

lity of residence for information about the separate collection centers for 

WEEE.This symbol on the electronic device indicates the separate collection of 

electrical and electronic equipment (Ref. Directive 2012/19/CE). Appropriate 

separate        waste collection for the subsequent start-up of the disposed appliance 

to environmentally compatible recycling and treatment and helps to avoid 

possible negative eects on the environment and on health and favors the recycling 

of the materials to which the product is composed.

TERMINAL DESCRIPTIONS
1. 230V ac power supply

2. 230V ac – power supply

3. Motor closing-

4.Motor opening-

5. Motor common-

6. +12 VDC power supply

7. -12 VDC power supply

1 2 3 4 5

6 7 8 9 10 11

IMPORTANT: Permanently connected appliances shall have 

an easily accessible disconnecting device incorporated 

into the wiring.

TRANSMITTER CODE MEMORIZATION

To memorize transmitter codes, the control panel must be in stable condition and the door in stop.

ONE-BUTTON MODE TRANSMITTER MEMORIZATION.

To perform memorization, press the PROG/RES programming button and release it after the beep. The red LED will light steadily, indicating that the device is 

ready to memorize the transmitter code.

From this moment any code received will be memorized. Then press the button of the transmitter on which we want to activate the automatism. The red LED 

will begin to flash accompanied by three beeps to confirm that the operation has been carried out correctly. After 4 seconds have elapsed since the last reception 

of a code, the device will automatically exit programming with two beeps, turning off the red led.

RADIO MEMORIZATION WITH TRANSMITTER (WITH HCS TRANSMITTER ONLY).

To use this system you must have already manually memorized at least one transmitter (with HCS coding). On a previously memorized transmitter, press the 

programming key or the 3 keys at the same time or key 1 and 4 of an ABEXO-type transmitter (with programmed HCS codes) to make it learn new radio 

commands. As confirmation, the red LED lights up accompanied by a beep sound. Pressing a key on the new transmitter emits 3 beeps to confirm memorization. 

For the 3-button version, the Stop button is pressed.

3-BUTTON MANUAL MEMORIZATION

Identical to the single-key procedure, but the Stop key must be pressed.

ERASING ALL CODES

Erasing all codes is achieved by "resetting" the memory. Press the PROG/RES key for 4 seconds. The red LED will flash several times and a series of beeps will 

indicate the erasure of all previously stored codes.

EXHAUSTED MEMORY INDICATION

Having exceeded 50 stored codes, in an attempt to store new codes, the red LED will start flashing accompanied by a series of beeps for 5 seconds.

RESET

To recover the automatic operation and closing times from factory data, remove the 220V power supply and set the DIP switches to the following position: 

DIP1: OFF

DIP2: ON DIP3: OFF DIPS4: ON

DIP5 - DIP6: UNAFFECTED

Remove any wires connected to terminal 9 and 4 and then power the panel to 220V.

An audible signal will warn that the process is successful. Reset the cables connected to terminal 9 and 4 and return the DIP switches to the position before the 

reset process began.

EC DECLARATION OF CONFORMITY: The manufacturer declares that the product complies with the regulations required by Directives 2014/35/EU, 

2014/30/EU, 2014/53/EU. At the same time, he declares that it is forbidden to put the aforementioned products into service until the machine to which they will 

be incorporated or of which they will be a part is identified and declared to comply with the conditions required by Directive 89/392 EEC and the national imple-

menting legislation, i.e. until the material covered by this declaration forms a whole with the final machine.

Complete with led indicator

FLASHER connection

terminals 4 (open)

and 5 (common)

8. Safety contact - photocell input

9. Commmon

10. P. Alt. External push button input 

STEP/STEP (N.O.)

11. mechanical border input or 8k2