Instructions for assembly and use
MADE
IN
ITALY
SH230
cod
.
APE-528/0230
www.abexo.tech
AB-00057.IT - rev.2/2024
TECHNICAL FEATURES
Before installing the product, be sure to disconnect the power supply. See the table
opposite for product characteristics:
PROGRAMMING OPERATION TIME
With the damper closed, set microswitch DIP2 to ON, DIP1 to OFF and DIP5/DIP6 to
ON. Enter programming by pressing the external button (connected between DIP9
and 10) or a previously inserted transmitter. A beep and blink will indicate the start
of programming, and the door will open until it reaches its end stop. Once reached
transmit the close command by pressing the external button or a transmitter. The
door will reach its closing limit and two beeps accompanied by a flashing will indica-
te the end of programming. Reposition the dips to the previous position.
PROGRAMMING AUTOMATIC CLOSING TIME
Programming can be done only with the door at rest and with DIP1 and DIP2
microswitches set to ON. Press the external button or inserted transmitter button; a
beep and a flash will indicate the start of programming. Finish by pressing the
button in question again after the desired time; Two beeps accompanied by a
flashing will confirm successful programming. Reposition the dips to the previous
position.
SETTING OPTIONS
DIP1: Timer/Auto closing selector:
· ON - automatic closing with timer.
· OFF - automatic closing disabled.
DIP2: Programming timer:
· ON - programming operation time (DIP1 OFF).
Programming closing time (DIP1 ON).
· OFF - programming time disabled.
DIP5
ON
ON
OFF
OFF
DIP6
ON
OFF
ON
OFF
Photocell and border disabled (BY DEFAULT))
Flush photocell and border enabled
Photocell and resistive border enabled.
Photocell enabled border disabled.
Power supply
Motor power
Fuse
Run time
Closing time
Code combinations
Number of codes
Programming of codes
Function selection
Frequency
Approval
Sensitivity
Application range
Antenna
Operating temperature
230V ac +-10%
1HP (1350 W)
6,3 A
Default 25 sec, programmable up to 2.5 minutes
Default 20 sec, programmable up to 3 minutes
72 million codes
50
Self-learning
Stores code function
433.92 Mhz
2014/35/UE ,2014/30/UE,2014/53/EU
Greater than -100 dBm
Standard 50m / man present 10m
Built-in
Da -10ºC a 70ºC
brand
CAME
ENTREMATIC
ABEXO
DITEC
TELCOMA
PUJOL
LUTEC
SUPERLIFT
NICE
BFT
JCM
model
TOP 433EE
ZEN
EGO 433
BIXLS2
TANGO 4SW
VARIO
HT12E
N3588
FLO
MITTO433
NEO10
brand
GIBIDI
APRIMATIC
ACM
model
AU03000 - AU03010 - AU01600
TM4
TX2 COLOR
SH230CONTROL UNIT
FOR SHUTTERS
AB Tecno Srl
Via Cicogna 95 - 40068 San Lazzaro di Savena (BO)
Tel: +39 051 6259580 - fax: +39 051 6259600
[email protected] - www.abexo.tech
ABEXO is a registered trademark
property of AB Tecno Srl
The technical characteristics can be subject to variations without advance notice. AB Tecno S.r.l. doesn’t take responsibilities for damages caused by the improper use of the device.
1 2 3 4 5 6
STANDARD RADIO CONTROL
COMPATIBILITY TABLE
HCS RADIO CONTROL
COMPATIBILITY TABLE
DIP3: Radio programming:
· ON - radio programming new transmitters enabled
· OFF - radio programming disabled
:
DIP4: Man Present (with jumper J2 closed hold down the transmitter Close button):
· ON - to realize the close, the transmitter button or external button must be held down. If
not held down, the operation stops.
· OFF - normal operation.
DIP5-6: Disable/Enable photocell and wire or resistive border:
By default, with jumper J2 open, the control unit is stepping, so pressing the single button
during opening or closing stops the door. Pressing it again will resume the reverse direction
from the previous direction. With jumper J2 closed, the transmitter will instead operate with
three buttons. (Open-Stop-Close). Recommended option for DEADMAN.