Abexo INDUS6 Assembly And Operating Instructions Download Page 1

1 - MAIN FEAT

 Power supply: 12-36 V ac/dc.

- Decoding: HCS with Manufacturer Code ABTECNO.

- Maximum number of remote controls that can be stored 500. Output: no. 

2 relays of

signal (max 1A).

2 - POWERING UP THE RECEIVER

The receiver is equipped with two LEDs (LED A and LED B) to signal the 

successful power supply to the board.

When the receiver is first turned on, these two leds light up briefly and then 

turn off.

3 - NORMAL OPERATION

 

During normal use, the 2 LEDs (LED A and LED B) are associated with the 

operation of the 2 output relays. Thus led A is associated with the 

operation of relay A while led B is associated with the operation of relay B. 

With the receiver powered and at rest, the leds will be off and will only 

light up when a channel of the radio control will activate the respective 

relay. With this function you will always have a visual indication of the 

correct operation of the receiver for each relay.
NB: it is not possible to drive the outputs during programming or cancella-

tion.

4 - RADIOCOMMAND MEMORIZATION

 The maximum number of radio 

controls that can be stored is 500 units. To store the radio controls in the 

receiver, programming mode must be enabled  by holding down the P-A 

button on the receiver until the LEDs provide a succession of visual signals 

a 2-second intervals, following the following order: LED A, LED B, LED A+B 

and then repeat the sequence in the same order.
Signals that provide an indication of which relay is to be activated with the 

remote control to be stored (led A relay 

A only, led B relay B only, led A+B both 

relays A and B).
Once you have identified the choice of 

the type of relay output desired, 

release the P-A button at the relevant 

visual indication of the LEDs.
At this point it is possible to memorise 

the radio control by pressing the 

button that you wish to associate with the selected relay (the button of the 

radio control that has to be memorised must be pressed until the two 

relays both light up for a few seconds to confirm correct memorisation).
NB: To store new radio controls, it will be necessary to repeat the operation 

from the beginning, by pressing the P-A button again.

5 - DELETION OF A REMOTE CONTROL

To delete the memory of a remote control incorrectly inserted in the 

receiver or to change its pairing to a particular relay you must carry out the 

following procedure:
- Keep the P-A button pressed until the leds provide a succession of visual 

signals, every 2 seconds, in the following order: led A, led B, led A+B then 

repeat the sequence in the same order. In this cancellation procedure it is 

not as important to select the relay as in the memorisation procedure so 

you can release the P-A button as soon as LEDs A and B provide visual 

indication.
- Once P-A button has been released, press P-B button until the two leds A 

and B will light up.
 - Press any button on the remote control to be erased from the receiver 

memory, until the two LEDs turn off, thus indicating correct deletion.
At the end of this procedure, none of the remote control keys will be
no longer recognised by the receiver.
NB: During these steps, a press of the P-A button on the receiver determi-

nes the exit from the erase mode.

MADE

 IN 

ITALY

INDUS6

cod.

APE-550/4006

INDUS RX

INDUS RX

cod.

APE-550/4033

IND-00007 - 2/2024

AB Tecno Srl

Via Cicogna 95 - 40068 San Lazzaro di Savena (BO)

Tel: +39 051 6259580 - fax: +39 051 6259600

[email protected]

www.abexo.tech

Multifrequency transmitter and receiver

Assembly and operating instructions

   Led 

B

Led 

A

   Pulsante 

P-B

Pulsante 

P-A

ANTENNA

GND

+12/36 VAC/DC

GND

RELAYS 1 (N.A.)

RELAYS  2 (N.A.)