USER SETTINGS
Menu items that are followed by the greater-than (>) symbol can be adjusted. For menu
items with read-on data (CURRENT, REACT & HEATER 1, INLET, OUTLET), the display
returns to normal mode if no key is selected within five minutes. In other menu selections,
the display returns to normal mode after about twenty seconds. Items lacking the (>)
symbol are only for information and cannot be reset or adjusted.
MAIN MENU
Display Menu
Press
SUBMENUS:
Press
MENU SELECTION
to change the setting
Ducting Options
A.Basic Setup
It is recommended to duct the Reactivation Outlet to an outside location.
The Reactivation ducting MUST be connected to a reactivation outlet.
Ducting should not be longer than six meters (20 feet). Set the ducting with the
least number of bends that can be attained.
Tips
The ducting should slope downwards away from the equipment.
Always duct the Reactivation Outlet, preferably to an outdoor location.
Notice: Sometimes, water may collect inside the Reactivation ducting. Thus, whenever
the ducting is moved, take care not to spill water in the machine or on the floor.
It is recommended to duct the Reactivation Outlet to an outside location.
B.Advanced Options
Duct inlet (2) to maximize performance
Allowing drier and colder air into the inlet increases the performance of the desiccant.
7
8