A720T (VHF) Service Manual V1.0
25/56
Chapter 7 Radio Debugging
7.1 The required test equipment
1. Stabilized power supply
1)The out power can be adjusted from 5V to 15V, and its current is 3A or even bigger.
2)standard voltage is 7.5V.
2. Ampere meter
1)Advanced ampere meter(17 gears and other functions)
2)Full scale can be set as 300mA or 3A.
3)It must use low loss cable.
3. Digital voltmeter
1)Voltage range: approximate FS=18V.
2)Input impedance: 1MΩ or even bigger.
4. Oscilloscope
1)Measuring range: DC to 30MHZ.
2)High accuracy measurement can be provided from 5 to 25MHz
5. Spectrum analyzer
Measurement range: DC to 1GHz or even bigger
6. Dummy load
16Ω
,
3W or even bigger
7. General-purpose tester
8920A/8921A/8920B/3920