4. Operations
User Configurations
Mode 1: One Screener / Switch to Safe Feed
This operational mode accommodates one screener, and the audio inputs/outputs are
embedded in the serial digital video input/output.
At the VIDEO trigger point, the VISUAL violation is masked with a switch to an
undelayed “AUX” safe feed, for the duration the VIDEO Panic Button is held down.
At the AUDIO trigger point, the AURAL violation is masked by a switch to the
“AUX” safe input feed, for the duration the AUDIO Panic Button is held down;
alternatively, the audio can be programmed to “Mute”.
The total delay is dependent on the AirCleaner model and format of the video. A set
of Reaction Time parameters are also available for the screener, for audio and video.
Figure 4-24. User Mode 1: One Screener / Switch to Safe Feed
Significant Parameters / MAIN Menu:
•
Screeners
= One
•
Total PGM Delay
= 8:00
(Value is only a suggestion)
•
On Video Trigger = Switch to AUX
•
On Audio Trigger = Switch to AUX
•
Video Reaction 1 = 1:15
(Value is only a suggestion)
•
Audio Reaction 1 = 1:15
(Value is only a suggestion)
Significant Parameters / OPTIONS Menu:
•
PGM IN Audio
= Embedded
•
AUX IN Audio
= Embedded
•
Embed. Audio OUT = ON