22
AirCleaner
•
User Guide
2. Installation
Panic Button Control Panel
Two Control Panels
If two Panic Button Control Panels are being used on the same AirCleaner chassis
(for Two-Screener operation), then the optional Panic Button “Y” Cable (Abekas part
number 9000-0990-00) must be used to interface between the GPI connector on the
AirCleaner chassis, and the two 33ft cables for each Panic Button Control Panel
(supplied with each Control Panel). Please refer to Figure 2-12 below.
Figure 2-12. Two Panic Button Control Panels and “Y” adapter cable connection.
Panic Button Control Panel Cable
(Supplied with Panic Button Control Panel Option)
The cable supplied with each Panic Button Control Panel is 33 feet (10 meters) in
length (Abekas part number 9000-0995-00). This cable can be substituted with any
“9-pin D” to “9-pin D” cable with male connectors at both ends. The maximum
length is 500 feet (152 meters) when using 22 gauge wires; the wiring is “straight-
through” pin-for-pin (no crossovers); this is the same wiring used in a standard RS422
9-pin D serial cable.
Panic Button “Y” Cable
(Option)
This option is used to connect two Panic Button Control Panels to the same
AirCleaner GPI connection. The “Y” cable connects to the GPI connector on the
AirCleaner chassis. Then two individual Panic Button Control Panels are connected
to each end of the “Y” cable; one panel for Screener 1 the other panel for Screener 2.
Each connector on the “Y” Cable is labeled accordingly.
Summary of Contents for AirCleaner
Page 2: ...ii AirCleaner User Guide ...
Page 10: ...x AirCleaner User Guide Table of Contents ...
Page 54: ...44 AirCleaner User Guide 3 Updating Software Firmware Updating Software Firmware ...
Page 100: ...90 AirCleaner User Guide 4 Operations Control Panel Menu Item Descriptions ...
Page 106: ...96 AirCleaner User Guide Index ...