NOTE: Make all connections in accordance with local codes.
Switch power off at service panel and lock the service discon-
necting means before wiring the unit. Detailed instructions
for electrical connection to the remote ventilator will be pack-
aged with the ventilator. Power cables, connectors, conduit
etc. not supplied.
Wiring the Hy-Ex Remote Ventilator HYEX-1.4 or 1.O:
1. Run three #14 AWG wires (black, white and green) in
conduit from the remote ventilator to the hood.
2. Remove ventilator’s top cover.
3. Feed conduit through the knock out into the base of the
ventilator. Secure with an appropriate connector.
4. Connect wires to the
terminal block inside the
ventilator; connect Black
to terminal labeled LINE/
Black, White to NEU/
White terminal and Green
to GND/ Ground termi-
nal. Replace ventilator’s
cover.
5. Run the 3-wire bun-
dled conduit from the ven-
tilator to the hood. Make
the electrical “whip” long
enough to reach to the
countertop below the in-
stalled hood.
Wiring from Service Panel
1. A 15A circuit is required for installation. It is recom-
mended to dedicate the circuit.
2. Run three #14 AWG wires: (black, white and green) in
conduit from service panel to hood.
3. Make the electrical “whip” long enough to reach the coun-
tertop below the installed hood.
Wiring at the Hood:
Refer to Page 9, “Wiring At Hood/Liner Re-Installation & Sys-
tem Test.
Electrical/Liner Installation
Hoods Using Hy-Ex Remote Ventilator
Liner
Hy-Ex Remote Ventilator
Hood Shell
120VAC
Motor Speed
Control
Top View
Liner Knock-out
Supply Knock-Out
Duct
Flexible
Metal
Conduit
Hood Stack
Ventilator Switch
Leg Knock-Out