ABB Welcome
®
— 5 —
4.2
Terminal description
Fig. 2
Terminal description
No.
Functions
1
Connector for device software update
2
Rotary switch to set the address of outdoor station (1-9)
3
Set feedback tone of pushbutton ON/OFF
4
Set general call to all indoor stations in one family
GC=ON, press button 1 and button 2, all indoor stations ring
For details, see
Chapter 5.2.
5
Configuration function of first and second round pushbutton
For details, see
Chapter 5.1.
6
Set the video mode to PAL or NTSC
OFF=PAL video mode
ON=NTSC video mode
7
Set default lock
OFF= set (Lock-GND) as default lock
ON= set (COM-NC-NO) as default lock
*Default lock is controlled by “unlock” button on indoor station.
8
Plug-in clamps (a, b) for connection
9
Plug-in clamps (Exit-GND) for exit button
10
Plug-in clamps (Lock-GND) for door opener
11
Plug-in clamps (COM-NC-NO) for floating output, door opener
12
Rotary switch to adjust default door lock release time (1-10 seconds)
13
Rotary switch to adjust loudspeaker volume
1
2
3
4
5
6
7
8
9
10
11
12
13