Interface description
Audio module on the video aluminum outdoor station

No.

Description

1

Connector for camera module

2

Connector for device software update

3

Plug-in clamps(COM-NC-NO)  for floating output, door opener (30 
V AC/DC 1 A)

4

Plug-in clamps(Lock-GND) for door opener (18 V 4A impulsive, 250 
mA holding)

5

Plug-in clamps(DC-GND) for additional power supply

6

Plug-in clamps(a-b) for Bus connection

7

Connector for induction loop module

8

Connector for next module

9

Connector for exit pushbutton

10

Connector for sensor to check the door status

11

Rotary switch to set the address of OS (1-9)

12

Set feedback tone of push button: ON/OFF

13

Configure push button as single column or double columns 
(ON= double columns; OFF= single column)

14

Configure function of 1st / 2nd push button
3->OFF, 4->OFF=call indoor station/call indoor station;
3->ON, 4->OFF=switch on lightings/call indoor station;
3->OFF, 4->ON=call guard unit / call indoor station;
3->ON, 4->ON=switch on lightings / call guard unit.

15

Adjust loudspeaker volume

16

Adjust door lock release time, 1-10 seconds

No.

Description

1

X100 X10 X1

Jumper to set the address of the indoor station.
Example: setting address 024

2

Master /Slave function

Only one indoor station in each apartment must be set as “Master” 
(Jumper should be  set as ‘M/S on’). All additional indoor stations  
in the same apartment must be set as “Slave” (Jumper should be 
set as ‘M/S off’).

3

Terminal resistor 

In video installations or mixed audio and video installations, the 
Jumper must be set as ‘RC on’ on the last device of the line.

4

a b = Bus connection

5

a potential free contact, such as a doorbell pushbutton

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

024

1

2

4

3

Indoor station

hundreds digits

X100

0

5

Summary of Contents for W2153 BL

Page 1: ... English Español ABB Welcome Quick Guide Audio Kit Audio Outdoor Station Teléfono con auricular y 3 pulsadores W2153 BL ...

Page 2: ......

Page 3: ... Content 004 009 010 015 English Español ...

Page 4: ...mm 2 x 0 28 mm UTP 5 2 x Two pairs each core Ø 0 5 mm 8 x 0 2 mm A 650 610 410 230 640 B 200 190 130 70 200 English Wiring Lock connection Type A Type B Type C Distance a b a b 110 240 V ON ON M S RC Add 001 2 wire bus line 110 240 V A B a b Exit GND Lock COM NC NO a b Exit GND Lock COM NC NO PS a b Exit GND Lock COM NC NO PS ...

Page 5: ...igure function of 1st 2nd push button 3 OFF 4 OFF call indoor station call indoor station 3 ON 4 OFF switch on lightings call indoor station 3 OFF 4 ON call guard unit call indoor station 3 ON 4 ON switch on lightings call guard unit 15 Adjust loudspeaker volume 16 Adjust door lock release time 1 10 seconds No Description 1 X100 X10 X1 Jumper to set the address of the indoor station Example settin...

Page 6: ...is button for more than 10 seconds until the blue LED is on The same operation will deactivate the funcition 3 Programmable button 3A Programmable for additional function e g call guard unit intercom etc 3B Default function of programmable button 1 is to release the 2nd lock on the default outdoor station 4 Blue LED 4A LED light blue auto unlock function is enabled 4B LED flashes slowly an incomin...

Page 7: ...tone function 3A Repeated ringtones indicate the function is enable default 3B Once ringtone indicates the function is disable 4 Hold Program 1 and Program 2 for 3 seconds to save the setting and exit the setting mode Step Description Blue LED Red LED 1 Pick up the handset hold Unlock for 3 seconds to enter the setting mode Flash times of red LED indicate the address of default outdoor station If ...

Page 8: ...he address setting 4 Press Unlock repeatedly to set the tens digit in the sequency 0 1 2 3 4 5 6 7 8 9 0 The value is indicated by the LED flash times The value will be resetore to 0 when Program 2 is pressed during the setting 5 Press Program 1 repeatedly to set the units digit in the sequency 0 1 2 3 4 5 6 7 8 9 0 The value is indicated by the LED flash times The value will be resetore to 0 when...

Page 9: ...P 5 2 x dos pares cada núcleo Ø 0 5 mm 8 x 0 2 mm A 650 610 410 230 640 B 200 190 130 70 200 Español Cableado Conexión de la cerradura Type A Type B Type C Distancia a b a b 110 240 V ON ON M S RC Añadir 001 Línea de bus de 2 cables 110 240 V A B a b Exit GND Lock COM NC NO a b Exit GND Lock COM NC NO PS a b Exit GND Lock COM NC NO PS ...

Page 10: ...4 Configurar funciones de los pulsadores 1 º 2 º 3 APAGADO 4 APAGADO llamar a estación interior llamar a estación interior 3 ENCENDIDO 4 APAGADO encender iluminación llamar a la estación interior 3 APAGADO 4 OENCENDIDO llamar al puesto de guardia llamar a la estación interior 3 ENCENDIDO 4 ENCENDIDO encender iluminación llamar al puesto de guardia 15 Ajusta el volumen del altavoz 16 Ajustar el tie...

Page 11: ...más de 10 segundos hasta que se encienda el LED azul La misma operación desactiva esta función 3 Botón programable 3A Programable para función adicional p ej llamar al puesto de guardia intercomunicador etc 3B La función predeterminada del botón programable 1 es abrir la 2 ª cerradura de la placa de calle predeterminada 4 LED azul 4A LED azul encendido función de apertura automática activada 4B LE...

Page 12: ...ca que la función está activada predeterminado 3B Tono de llamada único indica que la función está desactivada 4 4Mantenga pulsados Program 1 y Program 2 durante 3 segundos para guardar la configuración y abandonar el modo de ajuste Paso Descripción LED azul LED rojo 1 Coja el auricular mantenga pulsado Unlock durante 3 segundos para acceder al modo de configuración El número de destellos del LED ...

Page 13: ...rección 4 Pulse varias veces Unlock para establecer el dígito de decenas de la se cuencia 0 1 2 3 4 5 6 7 8 9 0 El valor lo indica el número de parpadeos del LED El valor volverá a 0 al pulsar Program 2 durante el ajuste 5 Pulse Program 1 varias veces para establecer el dígito de las unidades de la secuencia 1 2 2 4 5 6 7 8 9 0 El valor lo indica el número de parpadeos del LED El valor volverá a 0...

Page 14: ...14 ABB WELCOME AUDIO KIT Note ...

Page 15: ......

Page 16: ... 18 20010 Vittuone MI Italy For Non EU conturies ABB Xiamen Smart Technology Co Ltd No 7 Fangshan South Road Xiang An Xiamen Fujian 361000 China www abb com 2TMU200000M0081100 Copyright 2020 ABB All rights reserved Specifications subject to change without notice ...

Reviews: