Chapter 4
Tropos Routers Installation Guide, Models 6410 and 6420
49
FIGURE 22
6420 Power Consumption
TABLE 9
6420 Power Consumption (Watts) at Specified Input Voltage
Traffic level
Duty cycle
12V
24V
48V
Quiescent (beacon only)
0%
4.3
4.3
4.3
Normal
10%
6.1
5.7
5.7
Busy hour
30%
9.3
8.6
8.8
Maximum
50%
11.9
11.0
11.1