Operation Manual / TPR56-F + TPR61-F
1 Preliminary remarks / 1.4 Storage of new turbochargers and spare
parts
© Copyright 2021 . All rights reserved.
HZTL2490_EN
Rev.E
July 2021
1.4 Storage of new turbochargers and spare parts
Storage of new turbochargers and spare parts up to 6 months
New turbochargers and spare parts can be stored in their closed pack-
ages for 6 months from the date of delivery without additional moth-
balling measures.
Only dry rooms in which the relative humidity is between 40…70 % and
no condensation can form are suitable for storage.
Storage of new turbochargers and spare parts for more than 6
months
As the contents of the package are adapted as required, turbochargers
may also be delivered without a VCI label.
For parts with a VCI label on the package, the following instructions
must be observed.
Fig. 1:
V
olatile
C
orrosion
I
nhibitor (VCI)
WARNING
Health protection when handling VCI
VCI products are not hazardous in terms of the Ordinance on Hazard-
ous Substances. Nevertheless, the following points must be observed
when handling VCI:
u
Observe information in material safety data sheet
u
Ensure proper space ventilation.
u
Do not eat, drink or store food at the workplace while working with
VCI.
u
Clean hands and face after working with VCI.
u
For more information, see
.
Wear safety gloves to protect against mechanical hazards.
Every 6 months, the following mothballing measures are required:
u
Open package.
u
Remove VCI corrosion protection emitter from package and replace
with a new VCI corrosion protection emitter of the same kind. New
VCI corrosion protection emitters can be obtained from
.
Page
7
/
80