Operation Manual / TPL65-A32 / -A33 / -A36 + TPL69-A32 / -A33
Taking out of operation at short notice
9
Possibilities for emergency repair
9.1
Page 107
© Copyright 2016 ABB. All rights reserved.
N
ov
em
ber
2016
H
ZT
L2498_
EN
R
ev
is
ion
B
Taking out of operation at short notice
Possibilities for emergency repair
9.1
WARNING
Danger of fire and explosion due to lubricating oil leaks
Leaking oil may ignite on hot surfaces. This can result in serious injuries
to personnel or fatal accidents.
Cordon off danger area.
Raise the alarm and, depending on the situation, stop the engine.
Seal the oil leak.
Soak up oil and dispose of in an environmentally compatible manner.
Wear safety gloves against thermal risks.
CAUTION
Directives for taking out of operation
Serious damage to engine or property can be caused by non-
compliance with the directives for locking/blanking off the turbocharger
on the engine.
Follow the directives of the enginebuilder.
If the diesel engine must be capable of operation again as soon as possi-
ble after damage to the turbocharger (emergency repair), the following
possibilities are available:
Locking turbocharger rotor
Fitting the cover plate
Shutting off inlets and outlets
Turbocharger bypass
9
9.1