14
PCCU32 Tank Setup Screen
As the user sets up each tank in the Tank Setup screen, the lower
portion of the screen allows them to enter information to create a
strapping table. The user will need to enter the number of tank sections
and then complete the following information for each section (
x
being the
section number):
Section (
x
) Height
Section (
x
) Volume per unit height
Float Calibration in PCCU
While the LevelMaster is factory calibrated, occasionally there are
extenuating circumstances that may require the floats to be calibrated.
These circumstances may be as simple as a difference in the fluid
gravity.
Calibrating the float is actually based on determining a new level factor
and making a positive or negative adjustment to the level. This type of
adjustment is referred to as a bias. The user may determine the need to
set a bias if they have been comparing the reading level of each float
and comparing that to an actual measurement.
To further adjust the volumes due to an outside influence, namely a
damaged section of the tank, a strapping table allows for a more
accurate adjustment. This allows the user to make a correction based
only on the area damaged, rather than an adjustment to the entire
volume of the tank by setting a bias level. The calibration can be
performed by either MasterLink or PCCU software.
MasterLink
When communicating directly with the LevelMaster from a laptop using
MasterLink, during the setup process the user may enter a new value for
each float in the Setup screen. Under the Setup tab for this tank, the user
will see the section “Enter Gauging Tape Measurements Here:” For each
tank level, they may set a new level based upon the actual gauge level.
Refer to steps 8 and 9 in the Masterlink section of this manual.
PCCU32 Tank Setup Screen
As the user sets up each tank in the Tank Setup screen, notice in the
upper portion of the screen that they can enter a positive or negative bias
for each level.
Error Codes Troubleshooting
The following details the error codes that can be received from the
LevelMaster. If the following actions do not correct the problem, please
feel free to contact Totalflow Customer Service at 1-800-422-3097.