2TLC172121M0201 Rev.E  

ORIGINAL INSTRUCTIONS 

 

new.abb.com/low-voltage/products/safety-products 

 

  

SAFET Y PRODUCTS 

Tina 2A/2B Adapter unit 

Product Manual 

 

 
 
 
 
 
 
 
 
 

 

 

 

Summary of Contents for Tina 2A

Page 1: ...2TLC172121M0201 Rev E ORIGINAL INSTRUCTIONS new abb com low voltage products safety products SAFETY PRODUCTS Tina 2A 2B Adapter unit Product Manual...

Page 2: ...se uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems combustion systems railroad systems av...

Page 3: ...5 3 Product description 6 4 Installation 7 4 1 Installation precautions 7 4 2 Testing safety functions 7 5 Connections 8 5 1 Connection examples 9 6 Functions 10 6 1 LED indications 10 6 2 Informatio...

Page 4: ...umed that the reader of this document has knowledge of the following Basic knowledge of ABB safety products Knowledge of machine safety 1 4 Special notes Pay attention to special notes in the document...

Page 5: ...ions standards and the Machinery directive Warning Failure to comply with instructions operation that is not in accordance with the use prescribed in the instructions improper installation or handling...

Page 6: ...es prepared with a M20 entry This allows easy installation of the adapter unit within the physical enclosure of the safety device while keeping the status LED visible on the outside of the housing Tin...

Page 7: ...re starting up the system 4 2 Testing safety functions After each step the status of the input can be read on the monitoring device Steps for testing LED indication DYNlink signal output 1 Interrupt t...

Page 8: ...hnical data General Warning Information output signals shall never be used for safety purpose s Warning The connection cables are not monitored and shall therefore be installed within the same physica...

Page 9: ...2TLC172121M0201 Rev E 9 5 1 Connection examples Caution All cable colors according to ABB standard cables...

Page 10: ...s 10 ms Delay when the DYNlink input signal is connected to 0 VDC or disconnected 10 ms 10 ms Note If the DYNlink input signal is connected to 24 VDC longer than 70 ms the information output is set lo...

Page 11: ...tested regularly at least once every year to confirm that all the safety functions are working properly EN 62061 2005 A1 2013 A2 2015 EN ISO 13849 1 2015 Warning In case of breakdown or damage to the...

Page 12: ...input Check if there is 24 VDC on DYNlink signal input If yes check cable connections or the unit before No LED light Loss of power supply Check 24 VDC 0 VDC power supply Green but no DYNlink output...

Page 13: ...2TLC172121M0201 Rev E 13 9 Dimensions All dimensions are in mm Tina 2A Tina 2B...

Page 14: ...g intended for connection of any type of equipment Operating voltage 24 VDC 15 25 Total current consumption Maximum 25 mARMS Note Total current consumption is the internal supply current when there is...

Page 15: ...na 2B 20 g Color Black Directives Harmonized standards Conformity European Machinery Directive 2006 42 EC EN ISO 12100 2010 EN 62061 2005 Cor 2010 A1 2013 A2 2015 EN ISO 13849 1 2015 EN 60204 1 2018 I...

Page 16: ...2TLC172121M0201 Rev E 16 11 Declaration of conformity EC Declaration of conformity...

Page 17: ...2TLC172121M0201 Rev E 17 UK Declaration of conformity...