ABB Thomas&Betts Reddot The Deck Grommet Pro Installation Instructions Manual Download Page 2

WARNING

RISK OF SHOCK, DISCONNECT 

POWER BEFORE INSTALLATION.

FIGURE 6

Top of Deck Grommet™ Pro 

(A)

Flexible Cord 

(F)

Tighten (5 N.m) by screwing 

Flexible Cord Connector 

(E)

 

with Flexible Cord 

(F)

 to the 

Deck Grommet™ Pro 

(A)

.

FIGURE 7

GFCI

Receptacle
Installed

Device
Cover (

C)

Wiring Chamber

CAUTION

Electrical Connections shall be installed by a 

qualified electrician in accordance with the National

and Local Electrical Codes.
Be careful not to nick conductor insulation or outer 

sheathing.

2.3 Connect the supplied Flexible Cord 

(E)

 to the 

Deck Grommet™ Pro 

(A)

 using the supplied 

Flexible Cord Connectors 

(E)

 (see Figure 5 & 6).

2.3a Using standard electrical practices,connect the flexible 

cord conductor’s stripped end to the chosen power 
receptacle according to the receptacle manufacturer’s 
installation instructions and Figures 5, 6, 7 & 8. 

2.3b Tighten (5 N.m) Flexible Cord Connector 

(E)

 to the 

underside of the Deck Grommet™ Pro 

(A)

 (see Figure 6).

2. Electrical Wiring and Mounting Procedure

2.1 Select an approved tamper resistant and weather 

resistant type receptacle (15A or 20A) to be 

installed.

2.2 Install weatherproof outlet box (not supplied) to 

one of the floor joists adjacent to the Deck 

Grommet™ Pro 

(A)

 location. Follow the instructions 

supplied with the weatherproof outlet box.

2.2a The end of the weatherproof outlet box should line up 

with the center of the cut out hole (see Figure 3).

2.2b Connect AC power to the branch circuit.

2.2c Install the unstripped end of the Flexible Cord 

(F)

 into the 

end of the weatherproof outlet box. Make sure to leave a 
bend in the Flexible Cord

 (F) 

to the Deck Grommet™ Pro 

(A).

 

DO NOT 

make cord tight (see Figure 4).

2.2d Connect Flexible Cord conductors to the AC power 

supply conductors inside the weatherproof outlet box.

2.2e Tighten (5 N.m) Flexible Cord Connector 

(E)

 to the end of 

the weatherproof outlet box to secure the Flexible Cord 

(F)

 

(see Figure 4).

CL

FIGURE 3

End of weatherproof 

outlet box line up with 

center of cut out hole

Deck Board

(cut away view)

Cut Out Hole

Top view of Joist

FIGURE 4

Deck Board

Deck Grommet™ Pro 

(A)

2”

Flexible Cord 

(F)

with bend

Flexible Cord

Connector 

(E)

Joist

Joist

TA04771-1  A  Page 2 of 4

Weatherproof 

outlet box

FIGURE 5

Position Flexible Cord Connectors

as shown on the Flexible Cord.

Flexible Cord 

(F)

Conductors

Flexible Cord

Connector

 (E)

to the Deck

Grommet™ Pro 

(A)

Gland Nut

Flexible Cord

Connector

 (E)

to the

Weatherproof outlet box

Install Flexible Cord 

(F) 

flush with Flexible Cord

Connector

 (E)

CAUTION

When a nonGFCI protected receptacle is used, the branch 

circuit servicing the receptacle shall be GFCI protected.

Summary of Contents for Thomas&Betts Reddot The Deck Grommet Pro

Page 1: ...deck flooring thickness of 7 8 to a maximum of 1 5 8 and a minimum width of 5 1 4 The deck flooring must be a minimum of 2 feet above ground surface WARNING For outdoor use only Use this product only...

Page 2: ...ro A location Follow the instructions supplied with the weatherproof outlet box 2 2a The end of the weatherproof outlet box should line up with the center of the cut out hole see Figure 3 2 2b Connect...

Page 3: ...deck board see Figure 10 DO NOT OVER TIGHTEN 2 4c Turn on electrical power to the circuit Test function of the GFCI protection according to the manufacturer s instructions 3 Opening Deck Grommet Pro...

Page 4: ...n prompt notification of any warranted defect Thomas Betts will at its option repair or replace the defective product Misuse misapplication or modification of Thomas Betts Products immediately voids a...

Page 5: ...l corte C 1 Placa de cubierta para el dispositivo D 1 Adaptador del recept culo d plex E 2 Conector del cable flexible F 1 Cable trif sico flexible Tipo SJOOW 3 pies un extremo pelado un extremo sin p...

Page 6: ...do de tipo resistente a la manipulaci n y a la intemperie 15A o 20A para ser instalado 2 2 Instale la caja de salida a prueba de intemperie no suministrada a una de las viguetas del piso adyacente a l...

Page 7: ...Deck Grommet Pro A a la tabla de la plataforma vea la Figura 10 NO APRIETE EXCESIVAMENTE LOS TORNILLOS 2 4C Conecte la alimentaci n el ctrica al circuito Pruebe el funcionamiento de la protecci n GFCI...

Page 8: ...alquier defecto bajo la garant a Thomas Betts Corporation a su opci n reparar o reemplazar el producto defectuoso El mal uso la mala aplicaci n o modificaci n de los productos de T B anula inmediatame...