24/25
4.4.
Troubleshooting
What to do in case of:
•
Vehicle crash or Fire
→
Do not use the charger.
→
Make sure charger cannot be approached by anyone.
→
Turn off the power from the distribution panel upstream.
→
Contact your local ABB Service organization.
•
Damage of the connector or charge cable
→
Do not use the charger.
→
Contact your local ABB Service organization in order to arrange a replacement of
the cable.
•
Fluid leakage from the cooled CCS cable
The cable cooling system in the Terra HP Gen II charge post makes use of Huber and Suhner
CP3-002 coolant. This is a biodegradable, nonhazardous synthetic oil. In short summary of
the Huber and Suhner material safety data sheet:
o
CP3-002 is readily biodegradable according OECD criteria (>80%, tested according
OECD 301B).
o
German Water Hazard Class (WGK) is 1 (according VwVwS), which is the lowest
class: “slightly hazardous to water”.
o
There is no indication of bioaccumulation potential.
o
Mobility in soil is low.
The cooling system reservoir contains approximately 2 liters of CP3-002, and the cable con-
tains approximately 0.4 liters.
Charge posts produced as of September 2018 are equipped with an internal spill contain-
ment reservoir. This will capture coolant leaking inside the charge post, and can be emptied
during maintenance visits.
The cooling system is equipped with a fluid level sensor in the reservoir, and a pressure
drop sensor. In case a leak emerges it will be detected by either causing a pressure drop or
a drop of the fluid level in the reservoir, after which the pump it switched off immediately
and the system cannot be operated until it is repaired. This means that any potential spills
outside the charger will be of limited volume.
→
Be careful to avoid slipping on leaked/spilled product.
→
Take up with a liquid absorbing material (e.g. sand, diatomaceous earth, acid-or
universal binding agents) and proceed according to the waste disposal regulations.
Do not discharge into the sewage system/surface water/ground water/suboil as
well as the soil. In case of entry into waterways, soil or drains, inform the responsi-
ble authorities.