6.8
Local service portal operations
6.8.1
Start the local service portal
Preliminary requirements
•
The EVSE is ready for operation. No charge session is in progress.
•
No charge session is in progress.
Procedure
1. Open the front door of the EVSE. Refer to section
.
The HMI starts the local service portal application. The outside HMI goes into
idle mode. On the inside HMI, the authorization screen shows.
2. Enter the pin code.
3. Select
Continue.
6.8.2
Set the configuration parameters
1. Go to the configuration screen.
2. Wait for the system to load the data. This can take a few seconds.
3. Set
Authorization to ON or OFF. Use the toggle button.
4. Set the maximum AC input current in amperes.
The AC input current field has no maximum value. The correct AC input value is
the responsibility of the service engineer.
5. Save your changes.
6.8.3
Set the OCPP parameters
1. Go to the OCPP settings screen.
2. Wait for the system to load the data. This can take a few seconds.
3. Select and enter the data for these subjects:
•
OCPPJID
•
OCPPJURL
•
OCPPJPassword
•
Confirm password
4. Make sure that you type the URL or ID correctly and without spaces.
5. Obey the maximum number of allowed characters for URL and ID, that is 40.
6. Select
Set OCPP parameters to confirm the configuration parameters that you
entered.
7. Select
Save to save your changes.
Operation
9AKK108466A3703-EN | 001
63