Geometry of infrastructure
2.2.1
Required space for placing and maintaining the Terra 54
The Terra 54 requires a space of 1585 x 1480 mm. This space is calculated as follows:
- Size Charger W x D x H: 565 x 780 x 1900 mm.
- Front side 600 mm, in order to open the front door.
- Left and right side 510 mm, in order to open left and right door.
- Backside 100 mm, in order to guarantee an unimpeded airflow.
2.2.2
Ventilation and airflow of the Terra 54
The Terra 54 has an air inlet on the right side and outlet on the back side.
NOTICE
Free air flow
If necessary, take precautions to prevent snow or objects
from blocking the in- and outlets.