Commissioning
Product manual 2CKA001473B9664
│
01.03.2020
│19
Expert mode Special function
Floor Sensor
Original sensor
Application
Floor control
– If Combi mode is selected:
■
33.0 °C for max. value floor sensor
■
10.0 °C for min. value floor sensor
Frost protection
Yes
Min./Max.- values
■
Max. room 30.0 °C; Min. room 5.0 °C
■
Max. floor 50.0 °C; Min. floor 5.0 °C
Connected load (electrical)
1.000 W
Display internal temperature value
No
Offset
0.0 °C
Valve protection
No