background image


ABB Australia Pty Limited

For enquiries
ABB contact centre: 1800 60 20 20
E-mail: [email protected] 

www.stanilite.com.au

© Copyright 2020 ABB. All rights reserved. 

This document covers

What’s inside the box

Safety warning

Spitfire LED weatherproof

Installation instructions

Accessory kit

Removal instructions

Installation manual

Testing precautions

Warranty information

Troubleshooting guide

Troubleshooting guide

If you have installed and connected the fitting as per the instructions listed earlier and it does 
not function correctly, use the following table as a guide to fixing the problem. Look up the 
type of fault in the left column and check the possible causes from the right column.  

If the fitting still does not work after checking these possible causes, contact ABB customer 
service in Australia on 1800 60 20 20.

Thank you for choosing ABB product

Please read this document thoroughly before 
commencing installation and retain for future 
reference. Contact ABB customer service in 
Australia on 1800 60 20 20 if you need any 
assistance. The installation instructions were 
correct at the time of print. To reflect changes in 
technology and Australian standards; ABB 
reserves the right to amend the instructions 
without notice. Updated document can be found 
on the Stanilite website.

Safety warning

In Australia and New Zealand, only licensed 
electricians are permitted by law to work with 
240 volt electrical installations.
Do not attempt to install or connect this product 
unless you are a licensed electrician.
Turn off and isolate the electrical supply before 
connecting this fitting to the building wires.
Do not touch the terminals of the terminal block 
when the light fitting is energised.
The only user-serviceable parts are the lamp head 
assembly and battery pack. LED light source is 
not user-serviceable.
Do not attempt to service other parts of the 
fitting as this will void the warranty.
As the installer, it is your responsibility to ensure 
compliance with all relevant building and safety 
codes, (ie: AS/NZS 3000, AS/NZS 2293). Refer to 
the applicable standards for data and mains 

Important to note:

•  This product is designed for indoor and 

outdoor use.

•  Not suitable for installations where 

exposure to direct sunlight may occur.

cabling installation procedures and 
requirements.

Nexus LX (data cable system)

The Nexus range of emergency light fittings are 
designed to be connected together into a special 
communication network over a level 4 (or higher) 
high speed, single twisted pair data cable. The 
Nexus user and technical guide describes all you 
need to know to successfully install a Nexus project. 
Ask for it from your superviser, from your employer 
or from your nearest ABB product supplier. The 
network cabling of the building must be installed 
as per the procedure detailed in the Nexus user and 
technical guide. No mains or mains carrying cables 
are to be connected to the data terminals or cables.

Nexus RF (wireless system)

The Nexus RF range of light fittings are designed to 
communicate via a proprietary RF network, however 
the electrical installation of the fittings is identical 
to that of a standard non-monitored fitting.

9

A

K

K

10

6

9

30

A

0

6

70 - B - J

u

ly 2

0

20

No. Fault

Possible causes

1

LED light source and indicating LED not lit

AC supply not connected; 

or

AC supply turned off; 

or

Test switch damaged

2

LED light source is lit but indicating LED not lit

Test switch damaged; 

or

Battery not connected or faulty

3

LED light source does not switch to emergency 
mode when the test button is pressed

Test switch damaged; 

or

Battery not connected or faulty

4

LED light source works momentarily on emergency 
when the test button is pressed

Battery not yet charged (allow up to 24 hours)

 

I N S TA LL ATI O N  M A N UA L 

Stanilite®

Spitfire®_V2 LED weatherproof

Standard, Nexus® LX, Nexus RF

Doc no. 29-01150_4

Reviews: