26
2TLC010073M0201 Rev.G
8.10
Settings in custom mode
The Custom mode must be used to get a function which is not available with the preset
alternatives. The configuration parameters are set manually in custom mode.
Configuration
[C]
Reset
Timer delay
[d.XX]
Time
Log [LoG]
[CUS] Custom [C.01]
Equivalent
contacts
[r.01] Manual
reset
[r.02]
Automatic
reset
[d. - -] No delay
[d.01] Off-
delay
[d.02] On-delay
[d.03] Time
bypass
[d.04] Time
reset
[XXX/XX.X] 0 –
999 s
[Y.XX] 10 latest
errors
[C.02]
Antivalent
contacts
C.03] Pressure
sensitive
device
[C.04] Two-
hand device
8.11
Configuration in custom mode
9
- - -
Sto
CUS
r.01
C.01
PAS
000
000.
d.- -
1a
4c
6b
8a
9a
10
3b
5a
6a
2a
2b
1
2
3a
4a
4b
5b
5
7
7a
7c
8
3
4
6
8b
7b
5c
After a factory reset, the custom configuration mode is reached from the preset menu. Push
the increment button several times until you see the blinking "CUS" text on the display. This
entry is shown to indicate Custom mode.
Custom configuration mode can also be reached directly, by entering the correct password in
custom operation mode.
1.
Custom entry.
a. Push and hold the select button to step to the Configuration setting.
2. Configuration setting.
a. Push the increment button to select configuration [C.01-C.04].
b. Push the select button to step to the Reset setting.
3. Reset setting.