Health & Safety

Safety precautions

Be sure to read, understand and follow the instructions contained within this manual before and during use of the equipment. Failure
to do so could result in bodily harm or damage to the equipment.

Potential safety hazards

Electrical

Safety standards

This product has been designed to satisfy the requirements of IEC61010-1:2010 3rd edition 'Safety Requirements for Electrical
Equipment for Measurement, Control and Laboratory Use' and complies with US NEC 500, NIST and OSHA.

Safety conventions

EC Directive 89/336/EEC

Electrical

– In order to meet the requirements of the EC Directive 89/336/EEC for EMC regulations, this product must not be used in

an industrial environment.

End-of-life disposal

Cleaning

The complete recorder can be hosed down if it has been installed to IP66 / NEMA 4X standards – see Section 2, page 4. Warm water
and a mild detergent can be used.

Warning.

Installation and maintenance of this product must only be conducted by personnel authorized to work on electrical

installations and in accordance with relevant local regulations.

Warning.

To ensure safe use when operating this equipment, the following points must be observed:

Up to 240V AC may be present. Be sure to isolate the supply before removing the terminal cover.

Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating in conditions of
high pressure and / or temperature.

Safety advice concerning the use of the equipment described in this manual or any relevant Material Safety Data Sheets (where
applicable) can be obtained from the Company, together with servicing and spares information.

Warning.

In this manual, a warning is used to indicate a condition which, if not met, could cause serious personal injury and / or

death. Do not proceed beyond a warning until all conditions have been met.

Caution.

A caution is used to indicate a condition which, if not met, could cause minor or moderate personal injury and / or

damage to the equipment. Do not proceed beyond a caution until all conditions have been met.

Note.

A note is used to indicate important information or instructions that should be considered before operating the equipment.

The recorder contains a small lithium battery that must be removed and disposed of responsibly in accordance with
local environmental regulations.

The remainder of the recorder does not contain any substance that causes undue harm to the environment and must be
disposed of in accordance with the Directive on Waste Electrical and Electronic Equipment (WEEE). It must not be
disposed of in Municipal Waste Collection.

2

CI/RVG200–EN

Summary of Contents for ScreenMaster RVG200

Page 1: ...values and fuse requirements 4 Navigation navigating the user interface quickly and effectively 5 Menus overview menu familiarization 6 Basic setup steps required for first time use 7 Symbols and ico...

Page 2: ...sure to isolate the supply before removing the terminal cover Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating in conditions of high pressure a...

Page 3: ...rsonal injury and or death The user should reference this instruction manual for operation and or safety information This symbol when noted on a product enclosure or barrier indicates that a risk of e...

Page 4: ...lectrical and magnetic fields If this is not possible particularly in applications where mobile communications equipment is expected to be used screened cables within flexible earthed metal conduit mu...

Page 5: ...e terminals accept cables from 0 8 to 2 5 mm2 18 to 14 AWG The recorder conforms to Installation Category II of IEC 61010 All connections to secondary circuits must have basic insulation After install...

Page 6: ...e 2 neutral 3 ground or DC supply terminals 4 5 Fig 3 Accessing the recorder connection terminals Note Tighten terminal screws to a torque of 0 1 Nm 0 9 lbf in Fig 4 Power supply connections and fuse...

Page 7: ...0 9 8 7 6 5 4 1 2 18 17 16 15 14 13 12 3 11 10 9 8 7 6 5 4 1 2 13 12 L N Tx Tx Tx Rx 3 11 10 9 8 7 6 5 4 1 2 18 17 16 15 14 13 12 Tx Rx 1 2 3 4 5 6 1 2 3 4 5 RJ45 USB Inputs 1 to 6 RTD R THC Volt free...

Page 8: ...e 2 of 2 Display Operator menu icons page 1 of 2 Exit Operator menus return to previous view Exit display Display associated menus Access dialog Accept settings Fig 8 Navigating groups and views Swipe...

Page 9: ...ed by pressing the icon associated with the required function Select Group Configuration Operator Message Logging Select View Historical Review Screen Interval Acknowledge Alarm Auto Group Scroll Stop...

Page 10: ...ation based on the instrument s default configuration Configuration menu options comprise Common Groups Channels I O Functions Logic Editor Maths equations System Configuration Common Setup Number of...

Page 11: ...nable Bar graph markers Menu enables Batch if option enabled Enable Batch Recording Start Stop Abort Operator Login Batch Number Field 1 3 Title Channels Setup Source ID Trace color Zone Filter type S...

Page 12: ...mentation Master Modbus TCP Port Poll Rate Poll fail limit Response Timeout Client Authorization TCP TCP Client Access Authorized IP 1 6 Comms analog I P Comms analog I P Protocol Comms Digital I P Co...

Page 13: ...ay the Group Configuration dialog Select the channel s to be assigned to each group When allocation is complete press to return to the Common Configuration level 6 4 Set up the archive files 1 Press t...

Page 14: ...ssociated with that module 3 Configure parameters for each required module 4 When all parameters have been configured press to return to the I O page then to return to the System Configuration page 5...

Page 15: ...ration change File deleted Archive media inserted Archive media removed Archive media offline Archive media online Archive media full System error reset archiving Daylight time or daylight saving star...

Page 16: ...he contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB does not accept any responsibility whatsoever for potential errors or possible...

Reviews: